×
验证码:
换一张
忘记密码?
记住我
CORC
首页
科研机构
检索
知识图谱
申请加入
托管服务
登录
注册
在结果中检索
科研机构
清华大学 [1]
长春光学精密机械与物... [1]
河北大学 [1]
西安光学精密机械研究... [1]
内容类型
会议论文 [3]
期刊论文 [1]
发表日期
2012 [1]
2011 [1]
2010 [2]
×
知识图谱
CORC
开始提交
已提交作品
待认领作品
已认领作品
未提交全文
收藏管理
QQ客服
官方微博
反馈留言
浏览/检索结果:
共4条,第1-4条
帮助
已选(
0
)
清除
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
Development of a high accuracy laser interferometric dilatometer over the temperature range from 300 K to 1200 K
会议论文
9th Asian Thermophysical Properties Conference (ATPC), 2012-01-01
作者:
Ping, Sun Jian[1]
;
Qing, Liu Jian[2]
;
Yuan, Yang Xin[3]
;
Tao, Zhang Jin[4]
;
Duan Yuning[5]
收藏
  |  
浏览/下载:2/0
  |  
提交时间:2019/12/21
linear expansion coefficient
single frequency
laser interferometer
SRM738
relative deviation
combined standard deviation
An improved, real-time method for removing the cyclic error of a homodyne interferometer
会议论文
international symposium on photoelectronic detection and imaging 2012: laser sensing and imaging; and biological and medical applications of photonics sensing and imaging, beijing, china, may 24, 2011 - may 26, 2017
ZhaoSuwen
;
WenDesheng
;
ZhuShaolan
;
LiangShitong
收藏
  |  
浏览/下载:24/0
  |  
提交时间:2012/07/09
single frequency laser interferometer
error correction
real-time compensation
Lissajous figure
Anisotropic optical feedback of single frequency intra-cavity He-Ne laser
期刊论文
2010, 2010
Zhou Lu-Fei
;
Zhang Bin
;
Zhang Shu-Lian
;
Tan Yi-Dong
;
Liu Wei-Xin
收藏
  |  
浏览/下载:2/0
Autocollimation form dual-frequency laser diffraction grating interferometer design and analysis (EI CONFERENCE)
会议论文
2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering, CMCE 2010, August 24, 2010 - August 26, 2010, Changchun, China
Wang C.-G.
收藏
  |  
浏览/下载:19/0
  |  
提交时间:2013/03/25
Propose a new measurement system of autocollimation form laser grating heterodyne interferometer. Take grating diffraction and polarization optics as theoretical foundation
second
furthermore
combined with electronics knowledge to analyze the system. First
make use of autocollimation diffraction of grating
measurement information obtained by dual-frequency laser belongs to ac signal
the interferometer measurement system take grating pitch as measuring datum
the structure is simple
possess great gain and high signal-noise ratio
therefore
stable
completely overcome the disadvantages of DC level drift caused by light intensity variation of single-frequency laser
system can achieve nanometer resolution. 2010 IEEE.
reduce the impact of environmental factors
easy to install and debug
measurement error is small
©版权所有 ©2017 CSpace - Powered by
CSpace