CORC

浏览/检索结果: 共10条,第1-10条 帮助

已选(0)清除 条数/页:   排序方式:
A ratiometric fluorescent probe based on carbon dots assembly for intracellular lysosomal polarity imaging with wide range response 期刊论文
CHINESE CHEMICAL LETTERS, 2022, 卷号: 33, 期号: 2, 页码: 778-782
作者:  Zou, Guangyue;  Chen, Shuai;  Liu, Nazhen;  Yu, Yongliang
收藏  |  浏览/下载:18/0  |  提交时间:2022/04/12
Wide linear range and highly sensitive flexible pressure sensor based on multistage sensing process for health monitoring and human-machine interfaces 期刊论文
CHEMICAL ENGINEERING JOURNAL, 2021, 卷号: 412, 页码: 10
作者:  Zhong Mengjuan;  Zhang Lijuan;  Liu Xu;  Zhou Yaning;  Zhang MY(张懋熠)
收藏  |  浏览/下载:102/0  |  提交时间:2021/05/17
Exploiting ultra-large linear elasticity over a wide temperature range in nanocrystalline NiTi alloy 期刊论文
JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2020, 卷号: 57, 页码: 197-203
作者:  Sun Z;  Hao SJ;  Kang GF;  Ren Y;  Liu JP(刘俊鹏)
收藏  |  浏览/下载:52/0  |  提交时间:2020/11/30
A fluorometric aptasensor for bisphenol a based on the inner filter effect of gold nanoparticles on the fluorescence of nitrogen-doped carbon dots 期刊论文
MICROCHIMICA ACTA, 2019, 卷号: 186, 期号: 1, 页码: 28
作者:  Wang, Li[1];  Cao, Hai-Xia[2];  Pan, Chang-Gang[3];  He, Yu-Sheng[4];  Liu, Hong-Fei[5]
收藏  |  浏览/下载:77/0  |  提交时间:2019/12/24
Colorimetric adenosine aptasensor based on DNA cycling amplification and salt-induced aggregation of gold nanoparticles 期刊论文
MICROCHIMICA ACTA, 2018, 卷号: 185, 期号: 10
作者:  Kong, Caiyun;  Gao, Linna;  Chen, Zhengbo
收藏  |  浏览/下载:10/0  |  提交时间:2019/12/11
The aircraft autopilot design of parameters changing in a wide range (EI CONFERENCE) 会议论文
2011 International Conference on Electric Information and Control Engineering, ICEICE 2011, April 15, 2011 - April 17, 2011, Wuhan, China
Zhen D.; Yue Z.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Autopilot is an important part of aircraft  Under the action of the disturbance torque  for the flight parameters of aircraft Changing in a wide range  the range was about 16km  on the basic of analyzing the typical trajectory  the max height was about 5100m  the trajectory of feature points were selected  the deviation of lateral was about 12m  taking pitch control loop for example  the maximum angle of attack was about 3.6  a sub- PID autopilot was designed using classical control theory  the maximum elevator deflection was less than 5  using single-mode Transient suppression method  the maximum aileron deflection was less than 2  the overload due to control surface transition deflection was avoided when control parameters changing  the maximum roll was less than 5  the verification was done by non-linear simulation. The result showed that: the phase margin of autopilot was greater than 30  the response of overload can accurately track the given overload instruction. An autopilot design method of aircraft of parameter changes in a wide range was provided. 2011 IEEE.  the bandwidth was more than 14rad / s  the settling time was less than 0.7s  the maximum overshoot was 23.3%  
Control method research on wide flight envelope aerocraft (EI CONFERENCE) 会议论文
2nd Annual Conference on Electrical and Control Engineering, ICECE 2011, September 16, 2011 - September 18, 2011, Yichang, China
Duan Z.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
The flying qualities of aerocraft was directly effected by the autopilot  for the wide flight envelope aerocraft  on the basic of analyzing the typical trajectory  the three loop autopilots of roll stability  pitch and yaw were designed  using single-mode Transient suppression method  the overload due to control surface transition deflection was avoided when control parameters changing  the verification was done by non-linear simulation. The result showed that: Under the action of the disturbance torque  the maximum roll was less than 5  the range of the aerocraft was from 13.5km to 22.4km  the max height was about 5100m  the max deviation of lateral was about 42m  the maximum elevator deflection was less than 6.5 the control law was applicable within the effective range. An autopilot design method of wide flight envelope aerocraft was provided. 2011 IEEE.  
Cr image enhancement based on human visual characteristics (EI CONFERENCE) 会议论文
2010 International Conference on Computer Design and Applications, ICCDA 2010, June 25, 2010 - June 27, 2010, Qinhuangdao, Hebei, China
Zhang M.-H.; Zhang Y.-Y.
收藏  |  浏览/下载:18/0  |  提交时间:2013/03/25
The characteristic of digital CR medicine radiation image has wide dynamic range  abundant details and bad contrast  so it is necessary to enhance CR image to the need of doctor diagnosis. But the general enhancement algorithms don't consider human visual characteristics  so it puts forward CR medicine image adaptive enhancement algorithm combining the human visual property  which is more sensitive to smooth area noise compared with detail area noise  and makes image edge detail enhancement great in detail area  and detail enhancement little in smooth area  in which factor K is based on space change of image domain  accordingly gaining non-linear enhancement edge details of CR image. Experiment results demonstrate that the algorithm enhances CR image detail and CR image enhanced has good visual effect  so the method is fit for edge detail enhancement of CR medicine radiation image. 2010 IEEE.  
Design of a scene simulator in land-based aerospace lab with the man-made light source system based on quantum theory (EI CONFERENCE) 会议论文
Optoelectronic Devices and Integration II, November 12, 2007 - November 15, 2007, Beijing, China
Zhu X.; Yi W.; Fang W.; Yi H.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The paper presents a method with the technique of combination filtering of spectrum and the technique of DSP control for the simulation and recognition of the spontaneously lightening object and stellar map in the universe. The magnitude and the spectrum of a star can be simulated in a wide dynamic range. We established the mathematical models of the Vega's visible light spectrum and luminous flux density. Tungsten-halogen lamp as a light source is used to fit the linear light of the spontaneously lightening object in the universe. Through the experiment  it shows that the more sub-channels there are while filtering spectrum in the visible spectrum  and the more degrees the variable neutral density filters and the narrow-band attenuators have  more close to the actual spectrum the simulated spectrum is. It is proved that using the PID technique is beneficial to the output of the accurate and steady radiation from the light sources. The experiment shows that the using of this method can get perfect result in fitting and simulating the spectrum  magnitude and the stellar map of the spontaneously lightening object . The analysis of the consistent result and the experimental error is also discussed in detail in this paper.  
Amperometric determination of chemical oxygen demand using boron-doped diamond (BDD) sensor 期刊论文
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 卷号: 9, 页码: 2280-2285
作者:  Yu, Hongbin;  Wang, Hua;  Quan, Xie;  Chen, Shuo;  Zhang, Yaobin
收藏  |  浏览/下载:2/0  |  提交时间:2019/12/27


©版权所有 ©2017 CSpace - Powered by CSpace