Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography | |
Liu, Hongbo; Wang, Kun1; Peng, Dong; Li, Hui2; Zhu, Yukun3; Zhang, Shuang4; Liu, Muhan; Tian, Jie5,6 | |
刊名 | IEEE TRANSACTIONS ON MEDICAL IMAGING |
2016-12-01 | |
卷号 | 35期号:12页码:2546-2557 |
关键词 | Photoacoustic Tomography Model Matrix Acoustic Inversion Curve-driven Interpolated-matrix-model Inversion |
DOI | 10.1109/TMI.2016.2584120 |
文献子类 | Article |
英文摘要 | The computation of model matrix in the iterative imaging reconstruction process is crucial for the quantitative photoacoustic tomography (PAT). However, it is challenging to establish an outstanding model matrix to improve the overall imaging quality in PAT due to the noisy signal acquisition and inevitable artifacts. In this work, we present a novel method, named as the curve-driven-based model-matrix inversion (CDMMI), to calculate the model matrix for tomographic reconstruction in photoacoustic imaging. It eliminated the use of interpolation techniques, and thus avoided all interpolation related errors. The conventional interpolated-matrix-model inversion (IMMI) method was applied to evaluate its performance in numerical simulation, tissue-mimicking phantom and in vivo small animal studies. Results demonstrated that CDMMI achieved better reconstruction accuracy until IMMI kept increasing discrete points to 10000. Furthermore, the proposed method can suppress the negative influence of noise and artifacts effectively, which benefited the overall imaging quality of photoacoustic tomography. |
WOS关键词 | 3-DIMENSIONAL OPTOACOUSTIC TOMOGRAPHY ; RECONSTRUCTION ALGORITHM ; IMAGE-RECONSTRUCTION ; WAVELET ; MEDIA |
WOS研究方向 | Computer Science ; Engineering ; Imaging Science & Photographic Technology ; Radiology, Nuclear Medicine & Medical Imaging |
语种 | 英语 |
WOS记录号 | WOS:000391547700004 |
资助机构 | National Basic Research Program of China (973 Program)(2015CB755500) ; National Natural Science Foundation of China(81227901 ; Scientific Research and Equipment Development Project of Chinese Academy of Sciences(YZ201359) ; Key Research Program of the Chinese Academy of Sciences(KGZD-EW-T03) ; Chinese Academy of Sciences(2013Y1GA0004) ; China Postdoctoral Science Foundation(2014M550881 ; 61231004 ; 2015T80155) ; 61401462) |
内容类型 | 期刊论文 |
源URL | [http://ir.ia.ac.cn/handle/173211/14359] |
专题 | 自动化研究所_中国科学院分子影像重点实验室 |
作者单位 | 1.Chinese Acad Sci, Key Lab Mol Imaging, Inst Automat, Beijing Key Lab Mol Imaging, Beijing 100190, Peoples R China 2.Harbin Univ Sci & Technol, Coll Automat, Harbin 150080, Peoples R China 3.Shandong Univ, Sch Mech Elect & Informat Engn, Weihai 264209, Peoples R China 4.Northeastern Univ, Sinodutch Biomed & Informat Engn Sch, Shenyang 110819, Peoples R China 5.Xidian Univ, Sch Life Sci & Technol, Minist Educ, Engn Res Ctr Mol & Neuro Imaging, Xian 710071, Peoples R China 6.Chinese Acad Sci, Inst Automat, Key Lab Mol Imaging, Beijing 100190, Peoples R China |
推荐引用方式 GB/T 7714 | Liu, Hongbo,Wang, Kun,Peng, Dong,et al. Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography[J]. IEEE TRANSACTIONS ON MEDICAL IMAGING,2016,35(12):2546-2557. |
APA | Liu, Hongbo.,Wang, Kun.,Peng, Dong.,Li, Hui.,Zhu, Yukun.,...&Tian, Jie.(2016).Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography.IEEE TRANSACTIONS ON MEDICAL IMAGING,35(12),2546-2557. |
MLA | Liu, Hongbo,et al."Curve-Driven-Based Acoustic Inversion for Photoacoustic Tomography".IEEE TRANSACTIONS ON MEDICAL IMAGING 35.12(2016):2546-2557. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论