×
验证码:
换一张
忘记密码?
记住我
CORC
首页
科研机构
检索
知识图谱
申请加入
托管服务
登录
注册
在结果中检索
科研机构
长春光学精密机械与物... [4]
内容类型
期刊论文 [3]
会议论文 [1]
发表日期
2018 [2]
2016 [1]
2011 [1]
×
知识图谱
CORC
开始提交
已提交作品
待认领作品
已认领作品
未提交全文
收藏管理
QQ客服
官方微博
反馈留言
浏览/检索结果:
共4条,第1-4条
帮助
限定条件
专题:长春光学精密机械与物理研究所
第一署名单位
第一作者单位
通讯作者单位
已选(
0
)
清除
条数/页:
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
排序方式:
请选择
作者升序
作者降序
题名升序
题名降序
发表日期升序
发表日期降序
提交时间升序
提交时间降序
Laser ablation–induced synthesis and nonlinear optical characterization of titanium and cobalt nanoparticles
期刊论文
Journal of Nanoparticle Research, 2018, 卷号: 20, 期号: 10
作者:
Rao, Konda Srinivasa
;
Ganeev, Rashid A.
;
Zhang, Ke
;
Fu, Yue
;
Boltaev, Ganjaboy S.
收藏
  |  
浏览/下载:9/0
  |  
提交时间:2019/09/17
Nonlinear optics
Ablation
Absorption spectroscopy
Cobalt
Colloids
Deionized water
Ethylene
Ethylene glycol
Laser ablation
Nanoparticles
Refraction
Scanning electron microscopy
Synthesis (chemical)
Titanium
Two photon processes
Water absorption
Object Reconstruction Using the Binomial Theorem for Ghost Imaging
期刊论文
Ieee Photonics Journal, 2018, 卷号: 10, 期号: 6
作者:
Yue, Cong
;
Chen, Ping
;
Lv, Xiaofeng
;
Wang, Chenglong
;
Guo, Shuxu
收藏
  |  
浏览/下载:13/0
  |  
提交时间:2019/09/17
Image reconstruction
Algebra
Computation theory
Imaging techniques
Laser beams
Quantum optics
Speckle
Modelling of XCO2 Surfaces Based on Flight Tests of TanSat Instruments
期刊论文
Sensors, 2016, 卷号: 16, 期号: 11
作者:
Zhang, L. L.
;
T. X. Yue
;
J. P. Wilson
;
D. Y. Wang
;
N. Zhao
收藏
  |  
浏览/下载:20/0
  |  
提交时间:2017/09/11
The research of the accurate measure of static transfer function for the TDI CCD camera (EI CONFERENCE)
会议论文
3rd International Photonics and OptoElectronics Meetings, POEM 2010, November 2, 2010 - November 5, 2010, Wuhan, China
Guo-Ning L.
;
Long-Xu J.
;
Jian-Yue R.
;
Wen-Hua W.
;
Shuang-Li H.
收藏
  |  
浏览/下载:17/0
  |  
提交时间:2013/03/25
In the test course of static transfer function of TDI CCD camera
because of the influence that gets environmental and artificial etc. factor
the value of static transfer function measured at any time is between unceasing fluctuation
so
make accuracy reduce. To solve this problem
a kind of accurate measurement technique of static transfer function is put forward. First
before carrying out the measure of static quiet of transfer function
the best test point of transfer function of the TDI CCD camera must be determined
it is parallel to guarantee the rectangle target surface of parallel optical pipe and camera focal plane maintenance parallel
and again guarantee target strip in rectangle target and TDI CCD in camera focal plane maintenance vertical. TDI CCD catches rectangle target image
per 1000 lines of target mark image as a measures sample of static transfer function
exclude because of atmosphere tremble twisted
vague rectangle target mark image
retain 500 distinct and steady target mark image as measure sample set. Then
calculate the static transfer function of each measure sample respectively
take the average of all static quiet transfer function in measure sample set as the static transfer function of camera. Finally
the measure of the static transfer function for TDI CCD camera makes error analysis. Experimental results indicate that the value of the static transfer function of TDI CCD camera measured with this kind of method is 0.2923
with before measurement technique comparison
the value of static transfer function has raised 0.02
makes the accuracy of the measure of static transfer function have gotten raising.
©版权所有 ©2017 CSpace - Powered by
CSpace