CORC

浏览/检索结果: 共22条,第1-10条 帮助

限定条件    
已选(0)清除 条数/页:   排序方式:
Bose-Einstein condensation of a relativistic Bose gas trapped in a general external potential 期刊论文
http://dx.doi.org/10.1088/0305-4470/39/18/011, 2006
Su, G. Z.; Chen, J. C.; Chen, L. X.; 陈金灿
收藏  |  浏览/下载:1/0  |  提交时间:2013/12/12
Higgs boson mass from orbifold GUTs 期刊论文
PHYSICAL REVIEW D, 2006, 卷号: 73, 期号: 6, 页码: -
作者:  Gogoladze, I , Univ Delaware, Dept Phys & Astron, Bartol Res Inst, Newark, DE 19716 USA;  Gogoladze, I;  Li, TJ;  Shafi, Q
收藏  |  浏览/下载:11/0  |  提交时间:2012/08/02
Entropy function for 4-charge extremal black holes in type IIA superstring theory 期刊论文
PHYSICAL REVIEW D, 2006, 卷号: 74, 期号: 6, 页码: -
作者:  Cai, Rong-Gen;  Pang, Da-Wei;  Cai, RG , Chinese Acad Sci, Inst Theoret Phys, POB 2735, Beijing 100080, Peoples R China
收藏  |  浏览/下载:11/0  |  提交时间:2012/08/02
Higgs boson mass from orbifold GUTs with split supersymmetry 期刊论文
PHYSICS LETTERS B, 2006, 卷号: 639, 期号: 40972, 页码: 332-341
作者:  Gogoladze, Ilia;  Li, Tianjun;  Senoguz, V. N.;  Shafi, Qaisar;  Senoguz, VN , Univ Delaware, Bartol Res Inst, Dept Phys & Astron, Newark, DE 19716 USA
收藏  |  浏览/下载:10/0  |  提交时间:2012/08/02
Noncanonical MSSM, unification, and new particles at the CERN LHC 期刊论文
PHYSICAL REVIEW D, 2006, 卷号: 74, 期号: 12, 页码: -
作者:  Gogoladze, I , Univ Delaware, Dept Phys & Astron, Newark, DE 19716 USA;  Gogoladze, Ilia;  Li, Tianjun;  Senoguz, V. N.;  Shafi, Qaisar
收藏  |  浏览/下载:12/0  |  提交时间:2012/08/02
Intelligent MRTD testing for thermal imaging system using ANN (EI CONFERENCE) 会议论文
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
Sun J.; Ma D.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
The Minimum Resolvable Temperature Difference (MRTD) is the most widely accepted figure for describing the performance of a thermal imaging system. Many models have been proposed to predict it. The MRTD testing is a psychophysical task  for which biases are unavoidable. It requires laboratory conditions such as normal air condition and a constant temperature. It also needs expensive measuring equipments and takes a considerable period of time. Especially when measuring imagers of the same type  the test is time consuming. So an automated and intelligent measurement method should be discussed. This paper adopts the concept of automated MRTD testing using boundary contour system and fuzzy ARTMAP  but uses different methods. It describes an Automated MRTD Testing procedure basing on Back-Propagation Network. Firstly  we use frame grabber to capture the 4-bar target image data. Then according to image gray scale  we segment the image to get 4-bar place and extract feature vector representing the image characteristic and human detection ability. These feature sets  along with known target visibility  are used to train the ANN (Artificial Neural Networks). Actually it is a nonlinear classification (of input dimensions) of the image series using ANN. Our task is to justify if image is resolvable or uncertainty. Then the trained ANN will emulate observer performance in determining MRTD. This method can reduce the uncertainties between observers and long time dependent factors by standardization. This paper will introduce the feature extraction algorithm  demonstrate the feasibility of the whole process and give the accuracy of MRTD measurement.  
Integrated mach-zehnder micro-interferometer for gas trace remote sensing (EI CONFERENCE) 会议论文
ICO20: Remote Sensing and Infrared Devices and Systems, August 21, 2005 - August 26, 2005, Changchun, China
Chiarini M.; Bentini G. G.; Bianconi M.; Cerutti A.; Pennestri G.; Wang P.; She L.; Mazzoldi P.; Sada C.
收藏  |  浏览/下载:28/0  |  提交时间:2013/03/25
The realisation process and the preliminary tests on the performances of an integrated Mach-Zehnder Interferometer on LiNbO3 (Lithium Niobate) substrate is presented. The microsystem has been obtained by using medium mass Ion Implantation on X-cut Lithium Niobate crystals. The interferometer is formed by integrated optical channel waveguides: the phase shift between the two optical paths has been obtained  1mm 2 cross section and weights a few grams. The power consumption is in the milliwatt range. In the present work results obtained in the spectral window (0.4m-1.1m) will be presented. The performance of the device  without moving parts  evaluated on standard radiation sources  by applying a suitable electric field. The whole device is 60mm long  demonstrates that a spectral resolution better than 0.3nm can be obtained on 400nm spectral windows. The Micro-interferometer has been tested in laboratory with a calibrated cell containing NO2 gas and has demonstrated sensitivity in the ppb range if suitable optical paths are used. Its reduced dimensions and weights make these micro-systems ideal for a wide range of applications  has a 0.57times  spanning from Space Technology  Earth observation for Environment monitoring  to Safety and Security applications.  
Pseudo-dewetting behavior of low molecular weight poly(ethylene oxide) melts on mica surface 期刊论文
ACTA POLYMERICA SINICA, 2006, 期号: 9, 页码: 1125
Zhu, DS; Liu, YX; Chen, EQ; Li, M; Cheng, SZD
收藏  |  浏览/下载:14/0  |  提交时间:2013/09/24
A mesoscale cellular automaton model for curvature-driven grain growth 期刊论文
Metallurgical and Materials Transactions B-Process Metallurgy and Materials Processing Science, 2006, 卷号: 37, 期号: 1, 页码: 119-129
Y. J. Lan; D. Z. Li; Y. Y. Li
收藏  |  浏览/下载:14/0  |  提交时间:2012/04/13
Monte Carlo simulation of ferroelectric domain growth 期刊论文
Physical Review B, 2006, 卷号: 73, 期号: 1
B. L. Li; X. P. Liu; F. Fang; J. L. Zhu; J. M. Liu
收藏  |  浏览/下载:10/0  |  提交时间:2012/04/13


©版权所有 ©2017 CSpace - Powered by CSpace