CORC

浏览/检索结果: 共45条,第1-10条 帮助

限定条件        
已选(0)清除 条数/页:   排序方式:
Research on High Precision Membrane Mirror Forming Method 会议论文
2010
Liu C. Y.; Jia J. Q.; Jin G.; Zhong X.; Gu S.
收藏  |  浏览/下载:7/0  |  提交时间:2013/03/28
Real-time defogging processing of aerial images 会议论文
2010
Ji X. Q.; Feng Y. P.; Liu G.; Dai M.; Yin C. L.; Ieee
收藏  |  浏览/下载:9/0  |  提交时间:2013/03/28
ZnO films growth at different temperature on the substrate of Corning glass by MOCVD (EI CONFERENCE) 会议论文
2009 International Symposium on Liquid Crystal Science and Technology, August 2, 2009 - August 5, 2009, Kunming, China
Tang W.; Yang X.; Wang C.; Zhao C.; Gao X.; Yang J.; Liu B.; Liang H.; Zhao J.; Sun J.; Du G.
收藏  |  浏览/下载:17/0  |  提交时间:2013/03/25
SSA based decomposition of tool position trajectory for diamond turning of freeform optical surfaces (EI CONFERENCE) 会议论文
2009 International Conference on Manufacturing Science and Engineering, ICMSE 2009, December 26, 2009 - December 28, 2009, Zhuhai, China
Zhou X.; Duan N.; Xu P.; Lin C.; Liu Q.
收藏  |  浏览/下载:16/0  |  提交时间:2013/03/25
Study on sensing properties of a temperature-independent high pressure sensor base on tapered FBG (EI CONFERENCE) 会议论文
International Symposium on Photonics and Optoelectronics, SOPO 2010, June 19, 2010 - June 21, 2010, Chengdu, China
Shen R.; Liu Y.; Zhang X.; Lin W.; Cheng C.; Zhang Y.; Du G.; Qi L.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
The sensing properties with strain and temperature of tapered FBG had been researched both theoretically and experimentally. Based on tapered FBG and thin-wall strain cylinder structure  a novel temperature-independent high pressure sensor was fabricated and investigated. The tapered FBG performed as a chirped grating  whose bandwidth and reflection power broadened and increased when the pressure applied on it. Moreover  the bandwidth and the reflection power were temperature-independent. So the value of the strain can be obtained by detecting the reflection power. This method effectively solved the cross-sensitivity problem. The experiment results indicated that this sensor provided a measurement range of 040MPa with a sensitivity of 0.04w/MPa  low cost and good application prospect. 2010 IEEE.  
Growth of ZnO films under different oxygen partial pressures by metal organic chemical vapour deposition (EI CONFERENCE) 会议论文
2009 International Symposium on Liquid Crystal Science and Technology, August 2, 2009 - August 5, 2009, Kunming, China
Wang C.; Yang X.; Liu B.; Zhao C.; Tang W.; Yang J.; Gao X.; Liang H.; Zhao J.; Sun J.; Du G.
收藏  |  浏览/下载:19/0  |  提交时间:2013/03/25
Research on automatic Hartmann test of membrane mirror (EI CONFERENCE) 会议论文
5th International Symposium on Advanced Optical Manufacturing and Testing Technologies: Optical Test and Measurement Technology and Equipment, April 26, 2010 - April 29, 2010, Dalian, China
Zhong X.; Jin G.; Liu C.; Zhang P.
收藏  |  浏览/下载:20/0  |  提交时间:2013/03/25
Electrostatic membrane mirror is ultra-lightweight and easy to acquire a large diameter comparing with traditional optical elements  so its development and usage is the trend of future large mirrors. In order to research the control method of the static stretching membrane mirror  the surface configuration must be tested. However  membrane mirror's shape is always changed by variable voltages on the electrodes  and the optical properties of membrane materials using in our experiment are poor  so it is difficult to test membrane mirror by interferometer and null compensator method. To solve this problem  an automatic optical test procedure for membrane mirror is designed based on Hartmann screen method. The optical path includes point light source  CCD camera  splitter and diffuse transmittance screen. The spots' positions on the diffuse transmittance screen are pictured by CCD camera connected with computer  and image segmentation and centroid solving is auto processed. The CCD camera's lens distortion is measured  and fixing coefficients are given to eliminate the spots' positions recording error caused by lens distortion. To process the low sampling Hartmann test results  Zernike polynomial fitting method is applied to smooth the wave front. So low frequency error of the membrane mirror can be measured then. Errors affecting the test accuracy are also analyzed in this paper. The method proposed in this paper provides a reference for surface shape detection in membrane mirror research. 2010 Copyright SPIE - The International Society for Optical Engineering.  
Research on Automatic Hartmann Test of Membrane Mirror 会议论文
2010
Zhong X.; Jin G. A.; Liu C. Y.; Zhang P.
收藏  |  浏览/下载:9/0  |  提交时间:2013/03/28
The Algorithm of Extracting Energy Curve from X-ray Coherent Scatter Images 会议论文
2010
Liu T. H.; Liu J. X.; Qiao S.; Xie C. J.; Song J. Z.; Ieee
收藏  |  浏览/下载:3/0  |  提交时间:2013/03/28
Fabrication of ZnO thin film transistors based on the substrate of glass (EI CONFERENCE) 会议论文
2009 International Symposium on Liquid Crystal Science and Technology, August 2, 2009 - August 5, 2009, Kunming, China
Yang X.; Wang C.; Zhao C.; Tang W.; Gao X.; Yang J.; Liu B.; Qi X.; Du G.; Cao J.
收藏  |  浏览/下载:23/0  |  提交时间:2013/03/25


©版权所有 ©2017 CSpace - Powered by CSpace