Immunoassay by graphite furnace atomic absorption spectrometry using a metal chelate as a label | |
Wang, GL; Yuan, JL; Gong, BL; Matsumoto, K; Hu, ZD | |
刊名 | analytica chimica acta |
2001-12-03 | |
卷号 | 448期号:1-2页码:165-172 |
关键词 | immunoassay atomic absorption spectrometry alpha-fetoprotein bensulfuron-methyl |
英文摘要 | a new immunoassay method was developed by using graphite furnace atomic absorption spectrometry and edta-cd2+ chelate as a label. the new approach combined the use of edta-cd2+ chelate labeled streptavidin (sa), biotinylated antibody or antigen, and graphite furnace atomic absorption detection for both sandwich-type immunoassay and competitive-type immunoassay. the measurements of alpha -fetoprotein (afp) in human sera and bensulfuron-methyl (bsm) in water were used as the models to evaluate the usefulness of the method. the assays were carried out with 96-well microtiter plate as solid-phase carrier. after the immune reaction and biotin-streptavidin binding reaction, a solution of 0.2 m hno3 was added to each well to dissociate cd2+ in the immune complex on the solid-phase into the solution. the antigen concentration, was thus, determined by measuring the cd2+ absorbance of the solution with graphite furnace atomic absorption spectrometry. the present method gives detection limits of 0.12 ng ml(-1) for afp and 0.95 ng ml(-1) for bsm, respectively. the coefficient variations (cvs) of the method are less than 8.0%, and the recoveries are in the range of 90-110%. the concentrations of afp in 23 human serum samples were determined, and the results were compared with those of the independently determined by time-resolved fluoroimmunoassay method. a good correlation was obtained with a correlation coefficient of 0.993. (c) 2001 elsevier science b.v. all rights reserved. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | time-resolved fluorescence ; alpha-fetoprotein ; biotechnology |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000172458400018 |
公开日期 | 2015-11-10 |
内容类型 | 期刊论文 |
源URL | [http://159.226.238.44/handle/321008/138943] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, Dept Analyt Chem, Dalian 116012, Peoples R China 2.Lanzhou Univ, Dept Chem, Lanzhou 730001, Peoples R China 3.Waseda Univ, Dept Chem, Shinjuku Ku, Tokyo 1698555, Japan |
推荐引用方式 GB/T 7714 | Wang, GL,Yuan, JL,Gong, BL,et al. Immunoassay by graphite furnace atomic absorption spectrometry using a metal chelate as a label[J]. analytica chimica acta,2001,448(1-2):165-172. |
APA | Wang, GL,Yuan, JL,Gong, BL,Matsumoto, K,&Hu, ZD.(2001).Immunoassay by graphite furnace atomic absorption spectrometry using a metal chelate as a label.analytica chimica acta,448(1-2),165-172. |
MLA | Wang, GL,et al."Immunoassay by graphite furnace atomic absorption spectrometry using a metal chelate as a label".analytica chimica acta 448.1-2(2001):165-172. |