VALIDATION OF SOURCE BIASING METHOD FOR ITS USE IN CSNS BEAMLINE SHIELDING CALCULATION
Liang, TR ; Shen, F ; Liang, TJ ; Yin, W ; Yu, QZ ; Yu, CX
刊名RADIATION PROTECTION DOSIMETRY
2014
卷号162期号:3页码:208
ISSN号0144-8420
通讯作者Yin, W (reprint author), Chinese Acad Sci, Inst Phys, Beijing 100190, Peoples R China.
中文摘要The Chinese spallation neutron source (CSNS) is a high-performance pulsed neutron source, having 20 neutron beamlines for neutron scattering instruments. The shielding design of these beamlines is usually needed for Monte Carlo (MC) calculation, and the use of variance reduction methods is critical to carrying out an efficient, reliable MC shielding calculation. This paper discusses the source biasing method based on actual source term and geometry model of a CSNS neutron beamline. Dose distribution throughout the geometry model was calculated with the FLUKA MC code. Full analogue calculation and biased calculation were compared, and it was validated that the source biasing method can effectively promote the calculation efficiency.
资助信息National Science Foundation of China [91026009, 11174358, 11075203]
语种英语
公开日期2015-04-14
内容类型期刊论文
源URL[http://ir.iphy.ac.cn/handle/311004/59628]  
专题物理研究所_物理所公开发表论文_物理所公开发表论文_期刊论文
推荐引用方式
GB/T 7714
Liang, TR,Shen, F,Liang, TJ,et al. VALIDATION OF SOURCE BIASING METHOD FOR ITS USE IN CSNS BEAMLINE SHIELDING CALCULATION[J]. RADIATION PROTECTION DOSIMETRY,2014,162(3):208.
APA Liang, TR,Shen, F,Liang, TJ,Yin, W,Yu, QZ,&Yu, CX.(2014).VALIDATION OF SOURCE BIASING METHOD FOR ITS USE IN CSNS BEAMLINE SHIELDING CALCULATION.RADIATION PROTECTION DOSIMETRY,162(3),208.
MLA Liang, TR,et al."VALIDATION OF SOURCE BIASING METHOD FOR ITS USE IN CSNS BEAMLINE SHIELDING CALCULATION".RADIATION PROTECTION DOSIMETRY 162.3(2014):208.