Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror
D.S. Niu ; G.M. Wang ; B.Z. Gu ; Y. Yea
刊名Journal of Instrumentation
2013-03-28
卷号8期号:3页码:1-9
关键词Overall mechanics design (support structures and materials Instrument optimisation Optics Mirror Quality factor vibration analysis etc)
英文摘要
Active support scheme may decide the deformation of the optical surface figure of
the primary mirror. Two main active axial support schemes are often adopted to the thin meniscus primary mirror, one scheme is that the axial supports normal to the mirror bottom surface, and the other is that the active forces parallel to the optical axis. In order to compare the performance of the two support schemes, 1-m thin meniscus primary mirror is conducted. Finite element analysis (FEA) is employed to analyze the optical surface figures of the primary mirror, and optimizations are carried out by using ANSYS for each support scheme to obtain the locations and active forces.

The axial support force sensitivities are calculated for the two support schemes in a case that a single axial support has a force error of 0.5 N. The correction ability of the active support system for both of the support schemes are analyzed when an arbitrary axial support is failure. Several low order Zernike modes are modeled with MATLAB procedure, and active optics corrections are applied to these modes for the two active supports. The extra mirror surface error due to thermal deformation is also corrected with the two support schemes.
学科主题天文技术与方法
WOS记录号WOS:000316990700055
公开日期2014-02-11
内容类型期刊论文
源URL[http://ir.niaot.ac.cn/handle/114a32/729]  
专题南京天文光学技术研究所_中科院南京天光所知识成果_期刊论文
南京天文光学技术研究所_望远镜工程中心_期刊论文
推荐引用方式
GB/T 7714
D.S. Niu,G.M. Wang,B.Z. Gu,et al. Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror[J]. Journal of Instrumentation,2013,8(3):1-9.
APA D.S. Niu,G.M. Wang,B.Z. Gu,&Y. Yea.(2013).Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror.Journal of Instrumentation,8(3),1-9.
MLA D.S. Niu,et al."Performance comparison between two axial active support schemes for 1-m thin meniscus primary mirror".Journal of Instrumentation 8.3(2013):1-9.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace