Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST | |
Domier, C. W.1; Zhu, Y.1; Pereira, R. J.1; Steer-Furderer, J.1; Li, X.2; Chen, R.2; Xu, G.2; Sun, P.2; Luhmann, N. C., Jr.1 | |
刊名 | JOURNAL OF INSTRUMENTATION |
2022-02-01 | |
卷号 | 17 |
关键词 | Plasma diagnostics - interferometry, spectroscopy and imaging Analogue electronic circuits Nuclear instruments and methods for hot plasma diagnostics |
ISSN号 | 1748-0221 |
DOI | 10.1088/1748-0221/17/02/C02010 |
通讯作者 | Domier, C. W.(cwdomier@ucdavis.edu) |
英文摘要 | Ultrashort Pulse Reflectometry (USPR) is a plasma diagnostic technique involving the propagation of ultrashort duration (similar to few nsec) chirps which contain frequency components spanning large portions of the plasma density profile. Upon reflection, each frequency component reflects from a distinct density layer. The reflected wave packet is down-converted and passed through a multi-channel filter bank, with time-of-flight (TOF) measurements made on each of the filtered wave packets which are then used to reconstruct the electron density profile. Applied previously to the Sustained Spheromak Physics Experiment, UC Davis is updating this technique with higher power (>10X) sources, enhanced channel counts, and high speed customized TOF electronics. A 32 channel USPR system is being developed for the Experimental Advanced Superconducting Tokamak (EAST) device with frequencies spanning 52 to 92 GHz, reflecting from the right-hand plasma cut-off layer. The system will employ three monostatic transmit/receive horns each covering a different waveguide band. Each of the two higher frequency bands will have 8 distinct frequency channels, with the lowest frequency band, spanning 52 to 65 GHz, to have 16 receiver channels to better resolve the EAST scrape-off layer. With a pulse repetition rate of 1 MHz and simultaneous acquisition of all 32 TOF signals, electron density profiles may be obtained with time resolutions of as short as 3-6 mu sec. |
资助项目 | National Fusion Energy Program of China[2019FE03030000] |
WOS关键词 | DENSITY PROFILE |
WOS研究方向 | Instruments & Instrumentation |
语种 | 英语 |
出版者 | IOP Publishing Ltd |
WOS记录号 | WOS:000791423900002 |
资助机构 | National Fusion Energy Program of China |
内容类型 | 期刊论文 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/131519] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Domier, C. W. |
作者单位 | 1.Univ Calif Davis, Dept Elect & Comp Engn, 1 Shields Ave, Davis, CA 95616 USA 2.Chinese Acad Sci, Inst Plasma Phys, Hefei 230031, Peoples R China |
推荐引用方式 GB/T 7714 | Domier, C. W.,Zhu, Y.,Pereira, R. J.,et al. Ultrashort Pulse Reflectometry (USPR) diagnostic for EAST[J]. JOURNAL OF INSTRUMENTATION,2022,17. |