Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers | |
Liu, KL; Huang, TJ; Zhong, LZ; Li, ZZ; Wang, YS | |
刊名 | ACTA CHIMICA SINICA |
1998 | |
卷号 | 56期号:11页码:1112-1116 |
关键词 | sequential ICP spectrometer peak drift wavelength calibration |
ISSN号 | 0567-7351 |
其他题名 | Acta Chim. Sin. |
中文摘要 | Peak drifts of emission spectral lines recorded on a sequential ICP - AES spectrometer are the main factor that seriously decreases the precision and accuracy of sample determinations. The functional relationships between peak drift Delta lambda, and wavelength lambda, temperature T are found in this paper. The functional relationship curves Delta lambda - lambda, and Delta lambda - T were determined and expressed in the form of polynomial equations. The present study indicates that the curves Delta lambda - lambda for different monochromators are similar, but the curves Delta lambda - T for different monochromators are quite different. Based on the above - mentioned polynomial equations, an intelligent wavelength calibrating device (IWC) is developed for the sequential ICP spectrometer, which can replace a local thermostat of the sequential ICP - AES or the traditional line - profile method. The applications of the sequential ICP - IWC illustrate that the IWC device can significantly improve the precision of peak determination and have widespread prospects. |
英文摘要 | Peak drifts of emission spectral lines recorded on a sequential ICP - AES spectrometer are the main factor that seriously decreases the precision and accuracy of sample determinations. The functional relationships between peak drift Delta lambda, and wavelength lambda, temperature T are found in this paper. The functional relationship curves Delta lambda - lambda, and Delta lambda - T were determined and expressed in the form of polynomial equations. The present study indicates that the curves Delta lambda - lambda for different monochromators are similar, but the curves Delta lambda - T for different monochromators are quite different. Based on the above - mentioned polynomial equations, an intelligent wavelength calibrating device (IWC) is developed for the sequential ICP spectrometer, which can replace a local thermostat of the sequential ICP - AES or the traditional line - profile method. The applications of the sequential ICP - IWC illustrate that the IWC device can significantly improve the precision of peak determination and have widespread prospects. |
WOS标题词 | Science & Technology ; Physical Sciences |
类目[WOS] | Chemistry, Multidisciplinary |
研究领域[WOS] | Chemistry |
收录类别 | SCI |
原文出处 | |
语种 | 英语 |
WOS记录号 | WOS:000077372200012 |
公开日期 | 2013-11-15 |
内容类型 | 期刊论文 |
版本 | 出版稿 |
源URL | [http://ir.ipe.ac.cn/handle/122111/5987] |
专题 | 过程工程研究所_研究所(批量导入) |
作者单位 | Chinese Acad Sci, Inst Chem Met, Beijing 100080, Peoples R China |
推荐引用方式 GB/T 7714 | Liu, KL,Huang, TJ,Zhong, LZ,et al. Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers[J]. ACTA CHIMICA SINICA,1998,56(11):1112-1116. |
APA | Liu, KL,Huang, TJ,Zhong, LZ,Li, ZZ,&Wang, YS.(1998).Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers.ACTA CHIMICA SINICA,56(11),1112-1116. |
MLA | Liu, KL,et al."Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers".ACTA CHIMICA SINICA 56.11(1998):1112-1116. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论