Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers
Liu, KL; Huang, TJ; Zhong, LZ; Li, ZZ; Wang, YS
刊名ACTA CHIMICA SINICA
1998
卷号56期号:11页码:1112-1116
关键词sequential ICP spectrometer peak drift wavelength calibration
ISSN号0567-7351
其他题名Acta Chim. Sin.
中文摘要Peak drifts of emission spectral lines recorded on a sequential ICP - AES spectrometer are the main factor that seriously decreases the precision and accuracy of sample determinations. The functional relationships between peak drift Delta lambda, and wavelength lambda, temperature T are found in this paper. The functional relationship curves Delta lambda - lambda, and Delta lambda - T were determined and expressed in the form of polynomial equations. The present study indicates that the curves Delta lambda - lambda for different monochromators are similar, but the curves Delta lambda - T for different monochromators are quite different. Based on the above - mentioned polynomial equations, an intelligent wavelength calibrating device (IWC) is developed for the sequential ICP spectrometer, which can replace a local thermostat of the sequential ICP - AES or the traditional line - profile method. The applications of the sequential ICP - IWC illustrate that the IWC device can significantly improve the precision of peak determination and have widespread prospects.
英文摘要Peak drifts of emission spectral lines recorded on a sequential ICP - AES spectrometer are the main factor that seriously decreases the precision and accuracy of sample determinations. The functional relationships between peak drift Delta lambda, and wavelength lambda, temperature T are found in this paper. The functional relationship curves Delta lambda - lambda, and Delta lambda - T were determined and expressed in the form of polynomial equations. The present study indicates that the curves Delta lambda - lambda for different monochromators are similar, but the curves Delta lambda - T for different monochromators are quite different. Based on the above - mentioned polynomial equations, an intelligent wavelength calibrating device (IWC) is developed for the sequential ICP spectrometer, which can replace a local thermostat of the sequential ICP - AES or the traditional line - profile method. The applications of the sequential ICP - IWC illustrate that the IWC device can significantly improve the precision of peak determination and have widespread prospects.
WOS标题词Science & Technology ; Physical Sciences
类目[WOS]Chemistry, Multidisciplinary
研究领域[WOS]Chemistry
收录类别SCI
原文出处://WOS:000077372200012
语种英语
WOS记录号WOS:000077372200012
公开日期2013-11-15
内容类型期刊论文
版本出版稿
源URL[http://ir.ipe.ac.cn/handle/122111/5987]  
专题过程工程研究所_研究所(批量导入)
作者单位Chinese Acad Sci, Inst Chem Met, Beijing 100080, Peoples R China
推荐引用方式
GB/T 7714
Liu, KL,Huang, TJ,Zhong, LZ,et al. Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers[J]. ACTA CHIMICA SINICA,1998,56(11):1112-1116.
APA Liu, KL,Huang, TJ,Zhong, LZ,Li, ZZ,&Wang, YS.(1998).Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers.ACTA CHIMICA SINICA,56(11),1112-1116.
MLA Liu, KL,et al."Machanistic investigation of peak drift of a sequential inductively coupled plasma spectrometers".ACTA CHIMICA SINICA 56.11(1998):1112-1116.