Mechanical Property of Concrete Filled Steel Tube Reinforced Concrete (CFSTRC) Columns Subjected to two-opposite-side Fire
Xu, Lei1,2; Bao, Yan-Hong1; Wang, Wen-Da1; Sun, Jian-Gang1,2
2017
关键词Concrete filled steel tube reinforced concrete (CFSTRC) finite element methods fire resistance mechanical behavior two-opposite-side fire
卷号129
页码165-170
英文摘要The present study established a numerical investigation on the behavior of concrete filled steel tube reinforced concrete (CFSTRC) columns under combined loading and two-opposite-side fire. The FEA model was verified by the experimental results of CFST columns subjected to non-uniform fire. The comparison demonstrated an acceptable accuracy for the proposed FEA model. Afterwards, the FEA model was used to analyze the temperature distribution and failure modes of CFSTRC columns subjected to two-opposite-side fire, the influence of fire surface on the fire resistance of the column was also analyzed. The results show that the temperature distribution of the column section is biaxial symmetry, the highest temperature appears at the intersection of the fire surface and the symmetry axis, and the lowest temperature appears at the center of the columns; the load ratios and fire surface have a great influence on the mechanical property of the columns subjected two-opposite-side fire.
会议录PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017)
会议录出版者ATLANTIS PRESS
会议录出版地29 AVENUE LAVMIERE, PARIS, 75019, FRANCE
语种英语
资助项目Fundamental Research Funds for the Central Universities (China)[DC201502040201]
WOS研究方向Engineering
WOS记录号WOS:000414083700047
内容类型会议论文
源URL[http://119.78.100.223/handle/2XXMBERH/36298]  
专题国际合作处(港澳台办)
土木工程学院
通讯作者Xu, Lei
作者单位1.Dalian Minzu Univ, Sch Civil Engn, Dalian 116600, Peoples R China
2.Lanzhou Univ Technol, Key Lab Disaster Prevent & Mitigat Civil Engn Gan, Lanzhou 730050, Gansu, Peoples R China