Study on thermal and energy-saving performances of pipe-embedded wall utilizing low-grade energy | |
Liqun Zhou2; Chaojie Li1 | |
刊名 | Applied Thermal Engineering |
2020-06 | |
卷号 | 176期号:176 |
关键词 | Computational fluid dynamics Cooling Energy conservation Energy utilization Heat losses Mass transfer Structural design Transient analysis Building energy performance Computational fluid dynamics methods Design and optimization Heating and cooling Heating performance Inlet water temperatures Low energy buildings Thermal Performance |
ISSN号 | 13594311 |
DOI | 10.1016/j.applthermaleng.2020.115477 |
英文摘要 | Building energy performance improvement has received much attention in recent years. In this paper, the pipe-embedded wall integrated with low-grade energy was reported, which can be used to reducing the energy consumption effectively on space heating and cooling. The computational fluid dynamics (CFD) method was adopted to study the thermal performance of the pipe-embedded wall. An indoor experiment was conducted to verify the accuracy of the numerical model. The simulation data was agreed very well with the experimental result. The influence of inlet water temperature, mass flow rate and location of the embedded pipe has been evaluated under steady state. The results show that the pipe-embedded wall could achieve the best cooling or heating performance, when the pipes are in the middle location of the wall. The mass flow rate has little effect on the heat loss of the wall, but has a significant effect on the heat transfer of the circulating fluid. In the transient analysis, the pipe-embedded wall can reduce 13% of total heat gain in cooling season and 33% of heat loss in winter. The results indicate that the pipe-embedded wall has the advantages to utilize directly low-grade energy for reducing building cooling/heating load. The study also provides guidance for the design and optimization of low-energy buildings. © 2020 Elsevier Ltd |
WOS研究方向 | Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics |
语种 | 英语 |
出版者 | Elsevier Ltd |
WOS记录号 | WOS:000553967000053 |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/103343] |
专题 | 石油化工学院 |
通讯作者 | Chaojie Li |
作者单位 | 1.College of Chemical Engineering, Qingdao University of Science and Technology 2.College of Petrochemical Engineering, Lanzhou University of Technology |
推荐引用方式 GB/T 7714 | Liqun Zhou,Chaojie Li. Study on thermal and energy-saving performances of pipe-embedded wall utilizing low-grade energy[J]. Applied Thermal Engineering,2020,176(176). |
APA | Liqun Zhou,&Chaojie Li.(2020).Study on thermal and energy-saving performances of pipe-embedded wall utilizing low-grade energy.Applied Thermal Engineering,176(176). |
MLA | Liqun Zhou,et al."Study on thermal and energy-saving performances of pipe-embedded wall utilizing low-grade energy".Applied Thermal Engineering 176.176(2020). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论