Theoretical and Experimental Research on Temperature Rise Mechanism of Oil in the Sealed Cavity of Intra-Vane Type Pump | |
Li, Shaonian; Yang, Pan; Zhao, Ru; Liang, Tao; Zhou, Zhiyuan | |
刊名 | PROCESSES |
2022-03-01 | |
卷号 | 10期号:3 |
关键词 | vane pump sealed cavity temperature rise heat source heat emission route |
DOI | 10.3390/pr10030446 |
英文摘要 | To improve the performance of the intra-vane type pump and optimize the friction characteristics of the three friction pairs related to the vane cavity, theoretical analysis, numerical simulation, and experimental testing are used to study the mechanism of oil temperature rise in the sealed cavity of the vane pump. First, the heat generation source and heat dissipation routeways of the oil in the oil suction and oil discharge regions are analyzed, respectively. Thermodynamic modeling is conducted based on the principle of heat transfer. Then, the oil temperature rise caused by each heat generation source was simulated using the thermodynamic model. The influence of each heat generation source and heat generation route on the oil temperature rise change was analyzed and compared. Finally, a test system for oil temperature rise is designed, and the temperature changes at six positions of the experimental pump when working at three pressures are measured through experiments. Based on simulation and experimental results, the mechanism of oil temperature rise in the sealed cavity of the intra-vane type pump is analyzed and discussed. The experimental results show that the established thermodynamic model is very anastomotic to the experimental results. The experimental test value of temperature rise is greater than the calculated value. When the outlet pressure is 6 MPa, the maximum temperature rise of the theoretical calculation is 2 degrees C. Meanwhile, the maximum temperature rise of the experimental analysis is 3.5 degrees C. The maximum difference of temperature rise between theoretical calculation and experimental test is 1.5 degrees C. Therefore, the model can effectively predict the oil temperature rise in the sealed cavity of the intra-vane type pump and provide theoretical guidance for the design of similar pumps. |
WOS研究方向 | Engineering |
语种 | 英语 |
出版者 | MDPI |
WOS记录号 | WOS:000774452600001 |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/158089] |
专题 | 能源与动力工程学院 |
作者单位 | Lanzhou Univ Technol, Coll Energy & Power Engn, Lanzhou 730050, Peoples R China |
推荐引用方式 GB/T 7714 | Li, Shaonian,Yang, Pan,Zhao, Ru,et al. Theoretical and Experimental Research on Temperature Rise Mechanism of Oil in the Sealed Cavity of Intra-Vane Type Pump[J]. PROCESSES,2022,10(3). |
APA | Li, Shaonian,Yang, Pan,Zhao, Ru,Liang, Tao,&Zhou, Zhiyuan.(2022).Theoretical and Experimental Research on Temperature Rise Mechanism of Oil in the Sealed Cavity of Intra-Vane Type Pump.PROCESSES,10(3). |