Analysis of Effect of Primary Piping Diameter on Performance of Main Pump | |
Wang, Yan1; Cui, Huaiming1; Guo, Yanlei2; Mao, Yuanfan1; Duan, Yongqiang1; Li, Lei1; Su, Xianshun1 | |
刊名 | Hedongli Gongcheng/Nuclear Power Engineering |
2020-04-15 | |
卷号 | 41期号:2页码:125-129 |
关键词 | Efficiency Axial force fluctuation Pressure chamber Pressure fluctuation Structured mesh Three-dimensional model Transition sections Unsteady flow characteristics Unsteady pressures |
ISSN号 | 02580926 |
DOI | 10.13832/j.jnpe.2020.02.0125 |
英文摘要 | To the nuclear primary pump of PWR and its two different primary piping cold leg diameter configuration schemes, a three-dimensional model is established by combining the primary pump and the primary pipe, and the hexahedron structured mesh is used to perform the model partition and calculate the unsteady flow characteristics of the whole flow region. The unsteady pressure fluctuation characteristics in the pump and the pipe under different cold leg configuration schemes of the primary pipe are obtained. The results show that the primary pump efficiency decreases with the increasing of the cold section diameter, but the hydraulic loss decreases with the increasing of the cold section diameter, and the efficiency of the whole system increases by 1.3%; the pressure fluctuation amplitude of transition section can be significantly reduced with the increasing of the cold section diameter; the difference of pressure fluctuation amplitude between the inlet position of guide vane and the pressure chamber in the two schemes of cold section diameter is small, and the amplitude of the pressure fluctuation in the cold section is also small, and all of them show the characteristics of no cycle and no rule; the configuration of large diameter cold section will slightly reduce the amplitude of the axial force fluctuation. © 2020, Editorial Board of Journal of Nuclear Power Engineering. All right reserved. |
语种 | 中文 |
出版者 | Atomic Energy Press |
内容类型 | 期刊论文 |
源URL | [http://ir.lut.edu.cn/handle/2XXMBERH/115249] |
专题 | 能源与动力工程学院 |
作者单位 | 1.Science and Technology on Reactor System Design Technology Laboratory, Nuclear Power Institute of China, Chengdu; 610213, China; 2.Lanzhou University of Technology, Lanzhou; 730050, China |
推荐引用方式 GB/T 7714 | Wang, Yan,Cui, Huaiming,Guo, Yanlei,et al. Analysis of Effect of Primary Piping Diameter on Performance of Main Pump[J]. Hedongli Gongcheng/Nuclear Power Engineering,2020,41(2):125-129. |