Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips
L.Zhang; X.D.Li; Y.Y.Jin; Y.L.Zhang; X.M.Liu; Y.L.Chang
刊名Applied Surface Science
2019
卷号493页码:423-430
关键词SERS,Glucose sensing,Homogeneous phase,Silver nanotriangle,enhanced raman-scattering,hot-spots,silver,nanoparticles,hybrid,ag,spectroscopy,platform,oxidase,Chemistry,Materials Science,Physics
ISSN号0169-4332
DOI10.1016/j.apsusc.2019.07.053
英文摘要The advances in surface-enhanced Raman scattering (SERS) have resulted in significant improvements for sensing glucose, achieving a highly detecting sensitivity of the order of mu M. Highly sensitive glucose detection, however, is still a challenge due to extremely small Raman scattering cross section of glucose molecules and weak interaction between the molecules and the metal nanoparticles. Here, we designed a novel homogeneous SERS-based nanoplatform composing of the SERS tags and glucose oxidase in aqueous solution for a highly sensitive glucose detection. Adding glucose caused enzymatic oxidation reaction to etch the tip electric field (E) of silver nanotriangle. Thus, the decreased intensity of E was greatly amplified by the change of SERS signal (E-4 dependent), which resulted in an excellent glucose detection limit of 0.4 nM was firstly achieved. Furthermore, the nonlinear relationship between the decreased SERS intensity and the glucose concentrations was reasonably revealed based on theoretical calculations and deeply understanding of the enhancement mechanism, which is very useful in improving the sensitivity and accuracy of trace glucose detection. The as-prepared nanoplatform showed good sensitivity and high selectivity only through observing the SERS intensity change, which is potential for highly sensitive and practical glucose detection for clinical trace analyses.
语种英语
内容类型期刊论文
源URL[http://ir.ciomp.ac.cn/handle/181722/62802]  
专题中国科学院长春光学精密机械与物理研究所
推荐引用方式
GB/T 7714
L.Zhang,X.D.Li,Y.Y.Jin,et al. Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips[J]. Applied Surface Science,2019,493:423-430.
APA L.Zhang,X.D.Li,Y.Y.Jin,Y.L.Zhang,X.M.Liu,&Y.L.Chang.(2019).Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips.Applied Surface Science,493,423-430.
MLA L.Zhang,et al."Switching off the SERS signal for highly sensitive and homogeneous detection of glucose by attenuating the electric field of the tips".Applied Surface Science 493(2019):423-430.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace