Corrigendum to "High sensitivity FBG humidity sensor coated with graphene and polyimide films" [Opt. Fiber Technol. 66 (2021) 102635] (Optical Fiber Technology (2021) 66, (S106852002100184X), (10.1016/j.yofte.2021.102635))
Li, Ziwan2,3
2022-05
英文摘要We aimed to explore the effect of graphene films on polyimide-based humidity sensors in our published articles [1]. The results show that its sensitivity is 1.80 times that of the sensor coated with only polyimide film. After a lot of experiments in the later period, we believe that thicker polyimide film can lead to bigger wet hysteresis, which leads to measurement errors of this kind of sensor. We continue to explore the mechanism of action of graphene films by coating thinner polyimide films while keeping the graphene concentration consistent, and we found that the graphene film can effectively reduce the wet hysteresis effect and have a good measurement repeatability, as shown in Fig. 10(a) and (b) and its sensitivity are 1.53 and 1.61 times that of the sensor coated with thinner polyimide film when RH increases and decreases after coating the graphene film. The repeatability of the sensor is also good, Fig. 10(c) and (d) shows the repeatability test when only the polyimide film was coated and after coating the graphene film. We sincerely apologize to the editorial office and all readers. No conflict of interest exits in the submission of this manuscript, and manuscript is approved by all authors for publication. I would like to declare on behalf of my co-authors that the work described was original research that has not been published previously, and not under consideration for publication elsewhere, in whole or in part. All the authors listed have approved the manuscript that is enclosed. © 2021 Elsevier Inc.
语种英语
内容类型其他
源URL[http://ir.opt.ac.cn/handle/181661/95785]  
专题西安光学精密机械研究所_瞬态光学技术国家重点实验室
作者单位1.College of New Materials and New Energy, Shenzhen Technology University, Shenzhen; 518118, China
2.University of Chinese Academy of Sciences, Beijing; 100049, China;
3.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China;
推荐引用方式
GB/T 7714
Li, Ziwan. Corrigendum to "High sensitivity FBG humidity sensor coated with graphene and polyimide films" [Opt. Fiber Technol. 66 (2021) 102635] (Optical Fiber Technology (2021) 66, (S106852002100184X), (10.1016/j.yofte.2021.102635)). 2022-05-01.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace