Quench Protection Modeling of an HTS Magnet for MRI System | |
Shen, Boyang2; Chen, Xiaoyuan3; Liu, Huajun4; Ni, Zhipeng5; Shi, Yi4; Guo, Liang4; Zhang, Xintao4; Sheng, Jie1; Xie, Qi3; Zeng, Lei7 | |
刊名 | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY |
2021-11-01 | |
卷号 | 31 |
关键词 | High-temperature superconductor (HTS) HTS magnet Quench Finite element method (FEM) H-formulation Hot spot temperature |
ISSN号 | 1051-8223 |
DOI | 10.1109/TASC.2021.3089109 |
通讯作者 | Chen, Xiaoyuan(chenxy44@sina.com) |
英文摘要 | The High-temperature Superconducting (HTS) magnet is one of the most promising technologies to accommodate various high field applications. With the high magnetic field, the quench problem of HTS material should be considered with extra care, and the specific quench protection scheme should be projected. In this article, the modeling of the quench protection of an HTS magnet for the MRI system is presented. The modeling strategy was composed of two stages: Stage 1 the HTS magnet was in the normal operation circuit, and Stage 2 the HTS magnet was switched to the heat dissipation circuit. The 1st stage was based on the finite element method (FEM) using the H-formulation together with the thermal-coupled model, which simulated the current distribution of typical HTS tapes and showed the process of temperature increase when the hot source occurred. The 2nd stage was based on the analytical model to investigate the reasonable damping resistance and the hot spot temperature of the HTS magnet. |
WOS研究方向 | Engineering ; Physics |
语种 | 英语 |
出版者 | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
WOS记录号 | WOS:000694007400023 |
内容类型 | 期刊论文 |
源URL | [http://ir.hfcas.ac.cn:8080/handle/334002/125333] |
专题 | 中国科学院合肥物质科学研究院 |
通讯作者 | Chen, Xiaoyuan |
作者单位 | 1.Shanghai Jiao Tong Univ, Sch Elect Informat & Elect Engn, Shanghai 200240, Peoples R China 2.Univ Cambridge, Dept Engn, Elect Engn Div, Cambridge CB3 0FA, England 3.Sichuan Normal Univ, Sch Engn, Chengdu 610101, Sichuan, Peoples R China 4.Chinese Acad Sci, Hefei Inst Phys Sci, Hefei 230031, Anhui, Peoples R China 5.Neusoft Med Syst Corp, Superconducting Magnet & Gradient Coil Div, Shenyang 110167, Peoples R China 6.Southwest Jiaotong Univ, Key Lab Magnet Suspens Technol & Maglev Vehicle, Chengdu 610031, Peoples R China 7.Chengdu Univ Technol, Engn & Tech Coll, Dept Automat Engn, Leshan 614000, Peoples R China |
推荐引用方式 GB/T 7714 | Shen, Boyang,Chen, Xiaoyuan,Liu, Huajun,et al. Quench Protection Modeling of an HTS Magnet for MRI System[J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY,2021,31. |
APA | Shen, Boyang.,Chen, Xiaoyuan.,Liu, Huajun.,Ni, Zhipeng.,Shi, Yi.,...&Coombs, Tim.(2021).Quench Protection Modeling of an HTS Magnet for MRI System.IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY,31. |
MLA | Shen, Boyang,et al."Quench Protection Modeling of an HTS Magnet for MRI System".IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY 31(2021). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论