A portable and quantitative biosensor for cadmium detection using glucometer as the point-of-use device
Lingwen Zeng;  Junyu Gong;  Peisen Rong;  Chengshuai Liu;  Junhua Chen
刊名Talanta
2019
卷号198页码:412-416
关键词Cadmium Ion biosensor personal Glucose Meter point-of-use signal Amplification
英文摘要

As an ubiquitous heavy metal pollutantcadmium ion (Cd2+) is detrimental to food and human health even at low concentrations. Conventional methods require costly instruments and cannot meet the requirements of on-site analysis. Here we report the use of a personal glucose meter (PGM) as the point-of-use (POU) device for portable and quantitative detection of Cd2+. The specific recognition between the aptamer and Cd2+ trigger the recycling signal amplification process by exonuclease III (Exo III). After successive hybridization and cleavage reactions, numerous single-stranded DNA were liberated on the surface of the magnetic bead. An invertase-conjugated DNA that is complementary to the single-stranded DNA is introduced into the sensing system. After magnetic separation, the invertase conjugates hydrolyze sucrose into glucose, thus establishing direct conversion of Cd2+ concentration to glucose amount, which can be directly quantified by a PGM. Thanks to the synergistic signal amplification of Exo III and invertase, the POU device greatly improves the sensitivity for Cd2+ analysis, with a detection limit of 5 p.M. With the advantages of portability, cost-effectiveness, wide availability, and ease of use, the PGM-based detector has the potential to be used by the public as a routine tool for reliable and quantitative detection of Cd2+.

语种英语
内容类型期刊论文
源URL[http://ir.gyig.ac.cn/handle/42920512-1/10213]  
专题地球化学研究所_环境地球化学国家重点实验室
作者单位1.nstitute of Environment and Food Safety, Wuhan Academy of Agricultural Science, Wuhan 430065, China
2.State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550081, China
3.Guangdong Key Laboratory of Integrated Agro-environmental Pollution Control and Management, Guangdong Institute of Eco-environmental Science & Technology, Guangzhou 510650, China
4.School of Food Science and Engineering, Foshan University, Foshan 528000, China
推荐引用方式
GB/T 7714
Lingwen Zeng;Junyu Gong;Peisen Rong;Chengshuai Liu;Junhua Chen. A portable and quantitative biosensor for cadmium detection using glucometer as the point-of-use device[J]. Talanta,2019,198:412-416.
APA Lingwen Zeng;Junyu Gong;Peisen Rong;Chengshuai Liu;Junhua Chen.(2019).A portable and quantitative biosensor for cadmium detection using glucometer as the point-of-use device.Talanta,198,412-416.
MLA Lingwen Zeng;Junyu Gong;Peisen Rong;Chengshuai Liu;Junhua Chen."A portable and quantitative biosensor for cadmium detection using glucometer as the point-of-use device".Talanta 198(2019):412-416.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace