Detection of nitric oxide with Faraday rotation spectroscopy at 5.33 mu m(dagger)
Fang, Bo1,2; Yang, Na-na1,2; Wang, Chun-hui2,3; Zhao, Wei-xiong2; Xu, Xue-zhe2; Zhang, Yang2; Zhang, Wei-jun2,3
刊名CHINESE JOURNAL OF CHEMICAL PHYSICS
2020-02-01
卷号33
关键词Faraday rotation spectroscopy Mid-infrared Laser spectroscopy Nitric oxide
ISSN号1674-0068
DOI10.1063/1674-0068/cjcp1910182
通讯作者Zhao, Wei-xiong(wxzhao@aiofm.ac.cn) ; Zhang, Wei-jun(wjzhang@aiofm.ac.cn)
英文摘要We report the development of a static magnetic field Faraday rotation spectrometer for NO detection. A 5.33 mu m continuous-wave quantum cascade laser was used as the probing laser. Line absorption at 1875.81 cm(-1) ((2)pi(3/2)Q(3/2), upsilon=1 <- 0) was chosen for the detection. By using a Chernin type multipass cell, a detection precision of 1.15 ppbv (1 sigma, 1s) was achieved with an absorption pathlength of 108 m. This value was reduced to 0.43 ppbv by increasing the data-acquisition time to 15 s.
资助项目National Key Research and Development Program of China[2016YFC0202205] ; National Natural Science Foundation of China[41805104] ; National Natural Science Foundation of China[41875151] ; National Natural Science Foundation of China[41627810] ; Natural Science Foundation of Anhui Province[1508085J03] ; Youth Innovation Promotion Association CAS[2016383] ; CASHIPS Director's Fund[YZJJ2018QN7] ; CASHIPS Director's Fund[BJPY2019B02]
WOS关键词MODULATION SPECTROMETRY ; ELECTRONIC X-2-PI ; NO ; BAND ; CHEMISTRY ; DESIGN ; SYSTEM ; SCHEME
WOS研究方向Physics
语种英语
出版者CHINESE PHYSICAL SOC
WOS记录号WOS:000521229200006
资助机构National Key Research and Development Program of China ; National Natural Science Foundation of China ; Natural Science Foundation of Anhui Province ; Youth Innovation Promotion Association CAS ; CASHIPS Director's Fund
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/103507]  
专题中国科学院合肥物质科学研究院
通讯作者Zhao, Wei-xiong; Zhang, Wei-jun
作者单位1.Univ Sci & Technol China, Hefei 230026, Peoples R China
2.Chinese Acad Sci, Anhui Inst Opt & Fine Mech, Lab Atmospher Physicochem, Hefei 230031, Peoples R China
3.Univ Sci & Technol China, Sch Environm Sci & Optoelect Technol, Hefei 230026, Peoples R China
推荐引用方式
GB/T 7714
Fang, Bo,Yang, Na-na,Wang, Chun-hui,et al. Detection of nitric oxide with Faraday rotation spectroscopy at 5.33 mu m(dagger)[J]. CHINESE JOURNAL OF CHEMICAL PHYSICS,2020,33.
APA Fang, Bo.,Yang, Na-na.,Wang, Chun-hui.,Zhao, Wei-xiong.,Xu, Xue-zhe.,...&Zhang, Wei-jun.(2020).Detection of nitric oxide with Faraday rotation spectroscopy at 5.33 mu m(dagger).CHINESE JOURNAL OF CHEMICAL PHYSICS,33.
MLA Fang, Bo,et al."Detection of nitric oxide with Faraday rotation spectroscopy at 5.33 mu m(dagger)".CHINESE JOURNAL OF CHEMICAL PHYSICS 33(2020).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace