Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro
刊名JOURNAL OF CHROMATOGRAPHY A
2010
卷号1217期号:18页码:3167-3170
关键词Type-I counter-current chromatography Coil planet centrifuge The angle against the rotating centrifugal force field Retention of the stationary phase Resolution Dipeptide DNP-amino acid
ISSN号219673
英文摘要The performance of type-I high-speed counter-current chromatography was evaluated by changing the column inclination against the rotating centrifugal force field. The separations were performed with two different solvent systems composed of 1-butanol-acetic acid-water (4.75:0.25:5, v/v) (BAW) and hexane-ethyl acetate-methanol-0.1. M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acid as test samples, respectively. A set of short coiled columns connected in series is mounted around the holder hub in two different ways: in the parallel orientation, all column units are arranged in parallel to each other and mounted on the holder at various angles against the horizontal plane. In the zigzag configuration, the neighboring units of the same column are mounted symmetrically forming various angles apart. In the parallel configuration, for both the BAW and HEMW systems, Sf (the retention of stationary phase) first increased as the column angle decreased from 90° to 60° and then decreased, as the column angle further decreased from 60° to 0°, while Rs (peak resolution) continually declined over the entire column angle range from 90° to 0°. But, for both solvent systems, with the zigzag configuration, retention of stationary phase and resolution both decreased as the column angle decreased from 90° to 0°. In general, Sf and Rs for separation of dipeptides in the BAW system, from 90° to 15°, is better for the parallel orientation than for the zigzag configuration. However, at 0°, Sf and Rs are better for the zigzag orientation. In the DNP-amino acid separation with the HEMW system, retention of the stationary phase and Rs for the parallel orientation is better than that for the zigzag orientation from 90° to 30°, whereas from 30° to 0° the results are opposite. Over all results of our studies revealed that the formally used column orientation [5] at 90° inclination yields the highest peak resolution in both solvent systems.
学科主题Biochemistry & Molecular Biology ; Chemistry
收录类别SCI
WOS记录号WOS:000277373800020
公开日期2012-11-29
内容类型期刊论文
源URL[http://ir.xjipc.cas.cn/handle/365002/1784]  
专题新疆理化技术研究所_省部共建新疆特有药用资源利用重点实验室
作者单位NHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
推荐引用方式
GB/T 7714
Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography[J]. JOURNAL OF CHROMATOGRAPHY A,2010,1217(18):3167-3170.
APA Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2010).Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography.JOURNAL OF CHROMATOGRAPHY A,1217(18),3167-3170.
MLA Yang Yi,et al."Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography".JOURNAL OF CHROMATOGRAPHY A 1217.18(2010):3167-3170.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace