Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge | |
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro | |
刊名 | Journal of Chromatography A |
2010 | |
卷号 | 1217期号:48页码:7612-7615 |
关键词 | Compact type-I coil planet centrifuge Counter current chromatography Mounted column models DNP-amino acids Dipeptides Retention of the stationary phase Resolution |
ISSN号 | 219673 |
英文摘要 | Optimal positions of coiled separation columns on the type-I centrifuge were determined for four typical two-phase solvent systems to obtain the best separation efficiency (resolution and retention of stationary phase) for each with a suitable set of test samples. A set of short coiled columns is connected in series and mounted around the holder hub in four different ways: (model A) the tail of one unit with left-handedness was connected to the head of the next unit with right-handedness (TL-HR); (model B) the tail of one unit with left-handedness was connected to the tail of the next unit with right-handedness (TL-TR); (model C) the tail of one unit with left-handedness was connected to the tail of the next unit with left-handedness (TL-TL); (model D) the tail of one unit with left-handedness was connected to the head of the next unit with left-handedness (TL-HL). The results indicated that the performance of model D was the best among the four models. High revolution speed (800. rpm) is favorable to separation using the moderately hydrophobic solvent system of hexane-ethyl acetate-methanol-0.1. M HCl (1:1:1:1, v/v) (HEMW), while lower revolution speed (600. rpm) is beneficial to the separation with polar solvent system of 1-butanol-acetic acid-water (19:1:20, v/v) (BAW). |
学科主题 | Biochemistry & Molecular Biology ; Chemistry |
WOS记录号 | WOS:000284672400021 |
公开日期 | 2012-11-29 |
内容类型 | 期刊论文 |
源URL | [http://ir.xjipc.cas.cn/handle/365002/1776] |
专题 | 新疆理化技术研究所_资源化学研究室 |
作者单位 | NHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Xinjiang Indigenous Med Plants Resource U, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China |
推荐引用方式 GB/T 7714 | Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge[J]. Journal of Chromatography A,2010,1217(48):7612-7615. |
APA | Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2010).Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge.Journal of Chromatography A,1217(48),7612-7615. |
MLA | Yang Yi,et al."Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge".Journal of Chromatography A 1217.48(2010):7612-7615. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论