Determination of Total Selenium in Water by Hydride Generation Atomic Fluorescence Spectrometry
Xu Y. X. ; Luo K. L.
2012
关键词Fluorescence spectroscopy Test method Toal selenium in water Improved
英文摘要In order to establish a rapid and accurate hydride generation-atomic fluorescence spectrometry method for the determination of selenium content in water samples, the influence factors on Se nitrolysis in the water such as nitrolysis temperature and the amount of hydrochloric acid were studied. The authors determined a simple and practical test method that is to add 3 mL hydrochloric acid at 3 degrees C. We measured the precision and accuracy of the method by the standard liquid of 3, 6 and 10 mu g.L-1, and the test results were 2.96, 5.43 and 9.66 mg.L-1 The recovery varied from 90.50% to 98.67%. Meanwhile we tested 29 water samples by different methods. The error of standard sample was 8.95%similar to 25.46% by hydride generation-atomic fluoresence spectrometry in the GB/T 5750. 6-2006, and the error of standard sample was 1.33%similar to 3.40% by new method. Compared with the national standards of GB/T 5750. 6-2006, the method has the advantages of operating simplicity and and easy control, and it is also reliable and economical.
出处Spectroscopy and Spectral Analysis
32
2
532-536
收录类别SCI
语种英语
ISSN号1000-0593
内容类型SCI/SSCI论文
源URL[http://ir.igsnrr.ac.cn/handle/311030/26730]  
专题地理科学与资源研究所_历年回溯文献
推荐引用方式
GB/T 7714
Xu Y. X.,Luo K. L.. Determination of Total Selenium in Water by Hydride Generation Atomic Fluorescence Spectrometry. 2012.