Integrated Microfluidic System Containing Two Dimensional Separation and MS Identification for Proteomics Analysis | |
Liang Y(梁玉) ; Zhang LH(张丽华) ; Zhang YK(张玉奎) ; Liang Z(梁振) ; Dai ZP(戴忠鹏) ; Liang ZC(梁作成) | |
2011 | |
会议名称 | pittsburgh conference on analytical chemistry and applied spectroscopy |
会议日期 | 2011-3-13 |
会议地点 | 亚特兰大 |
页码 | 1274-0 |
通讯作者 | 张丽华 |
中文摘要 | microfluidic systems have been paid much attention to achieve high throughput proteomics analysis, with the advantages of improved portablility, low sample and reagent consumption, accelerated analytical speed, and facile integration. in this paper, the microchip containing scx monolith and c18 tip was developed and integrated with esi-ms/ms for two dimensional separation and ms identification of peptides. the scx monolith in the microchannel was prepared by the photopolymerization of ethylene glycol methacrylate phosphate and bisacrylamide in a trinary porogenic solvent, consisting of dimethylsulfoxide, dodecanol, and n,n-dimethylformamide, which exhibits high dynamic binding capacity and high permeability. the c18 tip was prepared by a fused-silica capillary with a pulled 5- m needle tip, packed with c18 particles (5 m, 300 å), inset and glued to the outlet of microchannel, coupled with esi-ms/ms directly, used as the separation column and the chip-to-ms interface. 4 g tryptic digests of membrane proteins extracted from rat liver were loaded on scx monolith by buffer c (0.1% formic acid water). then a series of stepwise elution with salt concentration of 250, 350, 500, 750 and 1000 mm ch3coonh4 adjusted by buffer c and buffer d (1000 mm ch3coonh4 at ph 3) was used to elute peptides from scx monolith onto c18 tip, followed by nano-rplc-esi-ms/ms analysis. after database searching using mascot with the significance threshold p<0.05, ions score cut-off 20, and bold red required, 295 proteins were successfully identified with 879 peptides, containing 120 transmembrane proteins, which demonstrated the applicability of such a system for proteomics analysis. |
合作状况 | 墙报 |
会议主办者 | 匹兹堡光谱学会 |
会议录 | pittsburgh conference on analytical chemistry and applied spectroscopy |
会议录出版者 | 待补充 |
会议录出版地 | 待补充 |
学科主题 | 分析化学 |
语种 | 英语 |
内容类型 | 会议论文 |
源URL | [http://159.226.238.44/handle/321008/116033] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
推荐引用方式 GB/T 7714 | Liang Y,Zhang LH,Zhang YK,et al. Integrated Microfluidic System Containing Two Dimensional Separation and MS Identification for Proteomics Analysis[C]. 见:pittsburgh conference on analytical chemistry and applied spectroscopy. 亚特兰大. 2011-3-13. |