Effects of morphology of nanostructured ZnO on direct electrochemistry and biosensing properties of glucose oxidase
Zhai YL ; Zhai SY ; Chen GF ; Zhang K ; Yue QL ; Wang L ; Liu JF ; Jia JB
刊名journal of electroanalytical chemistry
2011
卷号656期号:1-2页码:198-205
关键词DIRECT ELECTRON-TRANSFER SENSITIZED SOLAR-CELLS NANOWIRE ARRAYS HORSERADISH-PEROXIDASE MULTILAYER FILMS IMMOBILIZATION NANORODS NANOPARTICLES DEPOSITION NANOTUBES
ISSN号1572-6657
通讯作者liu jf
中文摘要an amperometric glucose biosensor based on the direct electron transfer (det) of glucose oxidase (gox) was developed and the enhanced catalytic current in presence of substrate was used to quantify glucose. gox was adsorbed onto nanostructured zno modified indium tin oxide (ito) electrodes. the goal of this work was to study the effects of morphology of nanostructured zno on det of gox and the sensor's analytical properties. nanostructured zno materials including nanorods (nrs) and nanoplates (nps) were electrochemical deposited onto ito and were characterized using scanning electron microscopy and x-ray diffraction. through adjusting the precursor of zn ions, electrolytes and controlling deposition charge (q in coulomb. c), different nanostructured zno with different size, shape and deposition density were obtained. gox was adsorbed onto nanostructured zno via layer-by-layer assembling to form gox and polylectrolyte multilayer films. compared to bare ito or ito deposited with nanostructured zno with other morphologies, gox immobilized onto zno nrs arrays (q = 0.1 c) gave higher current signals, exhibited reversible det (k(s,) 2.16 s(-1)), wide linear range (from 0.1 to 9 mm) with the limit of detection of 1.94 mu m and low apparent michaelis-menten constant (k(mapp,) 3.12 mm). (c) 2010 elsevier b.v. all rights reserved.
收录类别SCI收录期刊论文
语种英语
WOS记录号WOS:000291768300032
公开日期2012-06-11
内容类型期刊论文
源URL[http://ir.ciac.jl.cn/handle/322003/44563]  
专题长春应用化学研究所_长春应用化学研究所知识产出_期刊论文
推荐引用方式
GB/T 7714
Zhai YL,Zhai SY,Chen GF,et al. Effects of morphology of nanostructured ZnO on direct electrochemistry and biosensing properties of glucose oxidase[J]. journal of electroanalytical chemistry,2011,656(1-2):198-205.
APA Zhai YL.,Zhai SY.,Chen GF.,Zhang K.,Yue QL.,...&Jia JB.(2011).Effects of morphology of nanostructured ZnO on direct electrochemistry and biosensing properties of glucose oxidase.journal of electroanalytical chemistry,656(1-2),198-205.
MLA Zhai YL,et al."Effects of morphology of nanostructured ZnO on direct electrochemistry and biosensing properties of glucose oxidase".journal of electroanalytical chemistry 656.1-2(2011):198-205.