A self-circulation helium liquefaction system with five 4 K G-M cryocoolers
Xu, Xiangdong3; Xu, Dong2,3; Gong, Linghui3; Li, Laifeng3; Xie, Zuqi1; Zhao, Hongwei1; Guo, Xiaohong1
刊名CRYOGENICS
2011-06-01
卷号51页码:331-336
关键词Self-circulation Helium liquefaction G-M cryocooler
ISSN号0011-2275
DOI10.1016/j.cryogenics.2010.08.002
英文摘要A self-circulation helium liquefaction system (SCHLS) with five 4 K G-M cryocoolers is developed to supply liquid helium (LHe) for SECRAL (a superconducting ECR ion source used in Lanzhou city, China). LHe is vaporized in SECRAL and warmed up to room temperature. SCHLS will re-liquefy the helium gas at a rate of 83.2 L/day under normal atmosphere pressure. With SCHLS, SECRAL system can run online without any interruption of refilling LHe. (C) 2010 Elsevier Ltd. All rights reserved.
WOS研究方向Thermodynamics ; Physics
语种英语
出版者ELSEVIER SCI LTD
WOS记录号WOS:000291919100022
内容类型期刊论文
源URL[http://ir.impcas.ac.cn/handle/113462/23588]  
专题近代物理研究所_兰州重离子研究装置
通讯作者Li, Laifeng
作者单位1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100049, Peoples R China
3.Chinese Acad Sci, Key Lab Cryogen, Tech Inst Phys & Chem, Beijing 100190, Peoples R China
推荐引用方式
GB/T 7714
Xu, Xiangdong,Xu, Dong,Gong, Linghui,et al. A self-circulation helium liquefaction system with five 4 K G-M cryocoolers[J]. CRYOGENICS,2011,51:331-336.
APA Xu, Xiangdong.,Xu, Dong.,Gong, Linghui.,Li, Laifeng.,Xie, Zuqi.,...&Guo, Xiaohong.(2011).A self-circulation helium liquefaction system with five 4 K G-M cryocoolers.CRYOGENICS,51,331-336.
MLA Xu, Xiangdong,et al."A self-circulation helium liquefaction system with five 4 K G-M cryocoolers".CRYOGENICS 51(2011):331-336.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace