Low conductance injection tubes for storage cell targets
Stancari, M.1,2; Barion, L.1,2; Capiluppi, M.1,2; Ciullo, G.1,2; Contalbrigo, M.1,2; Dalpiaz, P. F.1,2; Drago, A.1,2; Lenisa, P.1,2; Statera, M.1,2; Steffens, E.3
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
2008-09-01
卷号594期号:2页码:126-131
关键词polarized nuclear targets storage cells spin structure of the nucleon
ISSN号0168-9002
DOI10.1016/j.nima.2008.06.019
英文摘要The effect of adding internal fins to the injection tube of a storage cell target filled with a polarized atomic beam source has been studied. The tube conductance and the atomic beam intensity at the exit of the injection tube have been measured, observing an unexpectedly large beam loss. Simulations of the atomic beam reproduce the observed attenuation only when the non-zero azimuthal component of the atom's velocity is taken into account. (C) 2008 Elsevier B.V. All rights reserved.
WOS关键词ATOMIC-BEAM SOURCE ; DEUTERIUM ; HYDROGEN
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics ; Spectroscopy
语种英语
出版者ELSEVIER SCIENCE BV
WOS记录号WOS:000259649900003
公开日期2010-10-29
内容类型期刊论文
源URL[http://ir.imp.cas.cn/handle/113462/5553]  
专题近代物理研究所_近代物理研究所知识存储(2010之前)
近代物理研究所_实验物理中心
通讯作者Stancari, M.
作者单位1.Ist Nazl Fis Nucl, I-44100 Ferrara, Italy
2.Univ Ferrara, Polo Sci Tecnol, I-44100 Ferrara, Italy
3.Univ Erlangen Nurnberg, Inst Phys, D-91058 Erlangen, Germany
4.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China
推荐引用方式
GB/T 7714
Stancari, M.,Barion, L.,Capiluppi, M.,et al. Low conductance injection tubes for storage cell targets[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2008,594(2):126-131.
APA Stancari, M..,Barion, L..,Capiluppi, M..,Ciullo, G..,Contalbrigo, M..,...&Wang, M..(2008).Low conductance injection tubes for storage cell targets.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,594(2),126-131.
MLA Stancari, M.,et al."Low conductance injection tubes for storage cell targets".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 594.2(2008):126-131.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace