Research of the capillary target-ion source system in on-line experiment | |
Zhao, ZZ; Yang, YF; Wang, TQ; Guo, YX; Guo, B; Fan, HM; Zu, KL; Wang, XD; Zheng, ZM; Liu, JH | |
刊名 | HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION |
2001-11-01 | |
卷号 | 25期号:4页码:1106-1112 |
关键词 | ion source capillary ionization on-line isotope separator separation efficiency |
ISSN号 | 0254-3052 |
英文摘要 | In order to study new isotopes and nuclear decay, properties in the A > 170 mass region, the laser ion source is needed and developed. For on-line isotope separator. it is required that the capillary ionization has a speciality, of low hot ionization efficiency and high ion extraction efficiency. The principle of the hot capillary ionization was described. The employment of Nb capillary reduces the temperature for forming the plasma potential and inhibitory hot ionization. The ionization tube is made of a Nb capillary of 2.2mm outside diameter, 1.7mm inside diameter and 30mm effective length. The temperature is 1600-2500K when the current is 40-100A. The target chamber is structured by Ta tube of 0.1mm wall thickness and windows of 6 mum Ta foil at two ends. Its maximum temperature is 2200K with the current 300A. The test experiment with on-line conditions at isotope separator ISOLAND has been performed. Yb-167 ( T-1/2 = 17.5min) isotope was produced in nuclear reaction O-18 (50MeV/u) + Ta-nat --> Yb-167. In the condition of target chamber temperature 2130K and capillary temperature 2130K, the total efficiency is 0.2%, This target-ion source system will be satisfied in laser ion source. |
WOS关键词 | SEPARATOR ; ISOTOPES |
WOS研究方向 | Physics |
语种 | 英语 |
出版者 | SCIENCE PRESS |
WOS记录号 | WOS:000172260400012 |
公开日期 | 2010-10-29 |
内容类型 | 期刊论文 |
源URL | [http://ir.imp.cas.cn/handle/113462/1495] |
专题 | 近代物理研究所_近代物理研究所知识存储(2010之前) 近代物理研究所_实验物理中心 |
通讯作者 | Zhao, ZZ |
作者单位 | Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Peoples R China |
推荐引用方式 GB/T 7714 | Zhao, ZZ,Yang, YF,Wang, TQ,et al. Research of the capillary target-ion source system in on-line experiment[J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,2001,25(4):1106-1112. |
APA | Zhao, ZZ.,Yang, YF.,Wang, TQ.,Guo, YX.,Guo, B.,...&Lei, XG.(2001).Research of the capillary target-ion source system in on-line experiment.HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION,25(4),1106-1112. |
MLA | Zhao, ZZ,et al."Research of the capillary target-ion source system in on-line experiment".HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION 25.4(2001):1106-1112. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论