Thermal design and performance of taper Injector II | |
Bai, Feng1; Niu, Xiaofei1,2; Wang, Xianjin1; Hu, Jianjun1; Hu, Yongping1; Zhang, Junhui1 | |
刊名 | CRYOGENICS |
2018-10 | |
卷号 | 95页码:29-35 |
关键词 | ADS Linac Cryomodule Cool-down Heat load |
ISSN号 | 0011-2275 |
DOI | 10.1016/j.cryogenics.2018.08.007 |
英文摘要 | A beta = 0.15 taper cavity cryomodule has been designed for China Accelerator Driven Sub-critical System Injector II (ADS) at the Institute of Modern Physics (IMP) of the Chinese Academy of Science (CAS). And ADS Injector II linac has accelerated 10 mA proton beam to 25 MeV in June of 2017. This cryomodule is the third cryomodule of ADS linac and contains five beta = 0.15 taper cavities and five 5.5 T solenoids operating at 4.2 K&1.05 Bar. First cool-down of this cryomodule was completed at the beginning of May in 2017. This paper will report the thermal design and performance of this taper cavity cryomodule. |
资助项目 | ITER project (China)[2014GB104000] |
WOS关键词 | CURRENT LEADS ; CRYOMODULE ; SHIELDS ; ITER |
WOS研究方向 | Thermodynamics ; Physics |
语种 | 英语 |
出版者 | ELSEVIER SCI LTD |
WOS记录号 | WOS:000449127900005 |
内容类型 | 期刊论文 |
源URL | [http://119.78.100.186/handle/113462/64423] |
专题 | 中国科学院近代物理研究所 |
通讯作者 | Zhang, Junhui |
作者单位 | 1.Chinese Acad Sci, Inst Modern Phys, Lanzhou 730000, Gansu, Peoples R China 2.Zhe Jiang Univ, Hangzhou 310027, Zhejiang, Peoples R China |
推荐引用方式 GB/T 7714 | Bai, Feng,Niu, Xiaofei,Wang, Xianjin,et al. Thermal design and performance of taper Injector II[J]. CRYOGENICS,2018,95:29-35. |
APA | Bai, Feng,Niu, Xiaofei,Wang, Xianjin,Hu, Jianjun,Hu, Yongping,&Zhang, Junhui.(2018).Thermal design and performance of taper Injector II.CRYOGENICS,95,29-35. |
MLA | Bai, Feng,et al."Thermal design and performance of taper Injector II".CRYOGENICS 95(2018):29-35. |