CORC  > 中国地质调查局  > 中国地质调查局
Quantitative Analysis of Sulfide Minerals by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Using Glass Reference Materials with Matrix Normalization Plus Sulfur Internal Standardization Calibration
Yuan, JH (Yuan Ji-Hai)8; Zhan, XC (Zhan Xiu-Chun); Fan, CZ (Fan Chen-Zi); Zhao, LH (Zhao Ling-Hao); Sun, DY (Sun Dong-Yang); Jia, ZR (Jia Ze-Rong); Hu, MY (Hu Ming-Yue); Kuai, LJ (Kuai Li-Jun)
刊名CHINESE JOURNAL OF ANALYTICAL CHEMISTRY
2012
卷号40期号:2页码:201-206
关键词Laser ablation-inductively coupled plasma-mass spectrometry Sulfide minerals Glass reference materials Anhydrite Multi-external standard and matrix normalization plus internal standardization calibration Relative sensitivity factor Microanalysis
ISSN号0253-3820
英文摘要A novel strategy for microanalysis of sulfides by LA-ICP-MS was established. This method took the relative sensitivity factor of Ca relative to S in anhydrite mineral reference material as a transition bridge, by which the relative sensitivity factors of interesting elements in glass reference materials relative to Ca could be converted into relative sensitivity factors relative to sulfide by the transition bridge and the quantitative analysis of multi-elements in sulfide minerals by multi-glass reference materials with matrix normalization plus sulfur internal standardization calibration. Twenty elements in the American multi-metal sulfide mineral reference material MASS-1 were analyzed using this method. The relative errors of major elements in MASS-1 were less than 10%, and the results of trace elements with reference values were nearly within the uncertainty of the preliminary values. The multi-elements in 12 sulfide single minerals were analyzed by applying this new method. The relative errors of the greatest number of major elements were less than 10%, which showed the results of most major elements were more accurate than those obtained by MASS-1 as calibration standard with matrix normalization plus internal standardization or internal standard calibration (chosen sulphur as an internal standard element). The trace element results agreed well with the calibrated results by MASS-1 with matrix normalization plus internal standardization or internal standard calibration. This method solved the problem of non-matrix matched standards, enabled accurate determination of the major composition of sulfur in sulfide minerals, and suggested a new approach for the analysis of sulfide minerals.
学科主题岩矿鉴定与测试
WOS关键词LA-ICP-MS ; TRACE-ELEMENTS
WOS研究方向Chemistry
语种英语
出版者ELSEVIER SCIENCE INC
WOS记录号WOS:000302781300003
内容类型期刊论文
源URL[http://119.78.100.197/handle/2HKVOGP0/39619]  
专题中国地质调查局
作者单位1.[Yuan Ji-Hai
2.Zhan Xiu-Chun
3.Fan Chen-Zi
4.Zhao Ling-Hao
5.Sun Dong-Yang
6.Hu Ming-Yue
7.Tianjin Inst Geol & Mineral Resources, Tianjin 300170, Peoples R China
8.中国地质科学院国家地质实验测试中心
推荐引用方式
GB/T 7714
Yuan, JH ,Zhan, XC ,Fan, CZ ,et al. Quantitative Analysis of Sulfide Minerals by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Using Glass Reference Materials with Matrix Normalization Plus Sulfur Internal Standardization Calibration[J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,2012,40(2):201-206.
APA Yuan, JH .,Zhan, XC .,Fan, CZ .,Zhao, LH .,Sun, DY .,...&Kuai, LJ .(2012).Quantitative Analysis of Sulfide Minerals by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Using Glass Reference Materials with Matrix Normalization Plus Sulfur Internal Standardization Calibration.CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,40(2),201-206.
MLA Yuan, JH ,et al."Quantitative Analysis of Sulfide Minerals by Laser Ablation-Inductively Coupled Plasma-Mass Spectrometry Using Glass Reference Materials with Matrix Normalization Plus Sulfur Internal Standardization Calibration".CHINESE JOURNAL OF ANALYTICAL CHEMISTRY 40.2(2012):201-206.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace