Flow velocity is relatively uniform in the coronary sinusal venous tree: structure-function relation | |
Wu, Hao ; Kassab, Ghassan S. ; Tan, Wenchang ; Huo, Yunlong | |
刊名 | JOURNAL OF APPLIED PHYSIOLOGY |
2017 | |
关键词 | coronary venous circulation morphometry hemodynamics area preservation LEFT-VENTRICULAR HYPERTROPHY PULSATILE BLOOD-FLOW ARTERIAL TREE WALL THICKNESS REDUCER STENT HEART RECONSTRUCTION RETROPERFUSION VASCULATURE MORPHOMETRY |
DOI | 10.1152/japplphysiol.00295.2016 |
英文摘要 | The structure and function of coronary venous vessels are different from those of coronary arteries and are much less understood despite the therapeutic significance of coronary sinus interventions. Here we aimed to perform a hemodynamic analysis in the entire coronary sinusal venous tree, which enhances the understanding of coronary venous circulation. A hemodynamic model was developed in the entire coronary sinusal venous tree reconstructed from casts and histological data of five swine hearts. Various morphometric and hemodynamic parameters were determined in each vessel and analyzed in the diameter-defined Strahler system. The findings demonstrate an area preservation between the branches of the coronary venous system that leads to relatively uniform flow velocity in different orders of the venous tree. Pressure and circumferential and wall shear stresses decreased abruptly from the smallest venules toward vessels of order -5 (80.4 +/- 39.1 mu m) but showed a more modest change toward the coronary sinus. The results suggest that vessels of order -5 denote a hemodynamic transition from the venular bed to the transmural subnetwork. In contrast with the coronary arterial tree, which obeys the minimum energy hypothesis, the coronary sinusal venous system complies with the area-preserving rule for efficient venous return, i.e., da Vinci's rule. The morphometric and hemodynamic model serves as a physiological reference state to test various therapeutic rationales through the venous route. NEW & NOTEWORTHY A hemodynamic model is developed in the entire coronary sinusal venous tree of the swine heart. A key finding is that the coronary sinusal venous system complies with the area preservation rule for efficient venous return while the coronary arterial tree obeys the minimum energy hypothesis. This model can also serve as a physiological reference state to test various therapeutic rationales through the venous route.; Natural Science Foundation of China [11372010, 11672006]; China MOST Grant [2014DFG32740]; SCI(E); PubMed; ARTICLE; 1; 60-67; 122 |
语种 | 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.pku.edu.cn/handle/20.500.11897/457195] |
专题 | 工学院 |
推荐引用方式 GB/T 7714 | Wu, Hao,Kassab, Ghassan S.,Tan, Wenchang,et al. Flow velocity is relatively uniform in the coronary sinusal venous tree: structure-function relation[J]. JOURNAL OF APPLIED PHYSIOLOGY,2017. |
APA | Wu, Hao,Kassab, Ghassan S.,Tan, Wenchang,&Huo, Yunlong.(2017).Flow velocity is relatively uniform in the coronary sinusal venous tree: structure-function relation.JOURNAL OF APPLIED PHYSIOLOGY. |
MLA | Wu, Hao,et al."Flow velocity is relatively uniform in the coronary sinusal venous tree: structure-function relation".JOURNAL OF APPLIED PHYSIOLOGY (2017). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论