CORC  > 北京大学  > 工学院
Knee MRI under varying flexion angles utilizing a flexible flat cable antenna
Jia, Fan ; Yuan, Hongyang ; Zhou, Diange ; Zhang, Jue ; Wang, Xiaoying ; Fang, Jing
刊名生物医学中的核磁共振
2015
关键词flexible MR receiver knee MRI flexion angle large FOV high SNR loopless antenna monopole antenna FFCA PHASED-ARRAY COIL MAGNETIC-RESONANCE GUIDEWIRE DESIGN
DOI10.1002/nbm.3264
英文摘要The aim of this study is to fabricate and test a novel flexible flat cable antenna (FFCA) for MRI of the knee at different flexion angles. The FFCA was made of a flat cable, a tuning/matching circuit and a signal transmission line. To test its feasibility and validity, in vitro and in vivo experiments were carried out on a 3.0 T MR scanner. The in vitro experiment suggested that the proposed FFCA could achieve a high signal-to-noise ratio (SNR) of 336, while the SNR of an eight-channel knee coil was 291, and phantom images from the FFCA are homogeneously distributed. In the in vivo experiment, the FFCA had a higher SNR of 169 in the region of interest and more than 48.5 cm of longitudinal coverage, while the corresponding values for the commercial coil were 153 and 22.5 cm. Finally, five sagittal knee images at different flexion angles were acquired. The FFCA could acquire satisfactory knee images at different flexion angles, with the advantages of simplicity, low cost, large field of view and high SNR. It may therefore be further used to improve MR image quality of the knee joint. Copyright (C) 2015 John Wiley & Sons, Ltd.; http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000351474500005&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=8e1609b174ce4e31116a60747a720701 ; Biophysics; Radiology, Nuclear Medicine & Medical Imaging; Spectroscopy; SCI(E); EI; PubMed; 0; ARTICLE; zhangjue@pku.edu.cn; cjr.wangxiaoying@vip.163.com; 4; 460-467; 28
语种英语
内容类型期刊论文
源URL[http://ir.pku.edu.cn/handle/20.500.11897/164068]  
专题工学院
推荐引用方式
GB/T 7714
Jia, Fan,Yuan, Hongyang,Zhou, Diange,et al. Knee MRI under varying flexion angles utilizing a flexible flat cable antenna[J]. 生物医学中的核磁共振,2015.
APA Jia, Fan,Yuan, Hongyang,Zhou, Diange,Zhang, Jue,Wang, Xiaoying,&Fang, Jing.(2015).Knee MRI under varying flexion angles utilizing a flexible flat cable antenna.生物医学中的核磁共振.
MLA Jia, Fan,et al."Knee MRI under varying flexion angles utilizing a flexible flat cable antenna".生物医学中的核磁共振 (2015).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace