CORC  > 北京大学  > 信息科学技术学院
Mechanical strength of anchor-microbeam combined structure fabricated by silicon-on-glass process
He, Jun ; Huang, Xian ; Zhang, Li ; Zhao, Danqi ; Yang, Fang ; Wang, Wei ; Zhang, Dacheng
2014
英文摘要To investigate the mechanical strength of the anchor-microbeam combined structure, two series of devices (bonding quality testing devices and torsional strength testing devices) are designed and fabricated by the silicon-on-glass process. A novel array-shaped anchor scheme is presented, which has been compared with the conventional single anchor. The experimental results have shown that the bonding quality of the anchor degenerated severely when the bonding area became very small (2). The testing results of bonding quality testing devices demonstrated that the presented array-shaped anchor design helped to improve the anodic bonding yield. According to the bending fracture test of the torsional strength testing devices, the array-shaped anchor design had an almost equal torsional strength compared with the single anchor with the same occupied area. Moreover, the torsional strength of the array-shaped anchor was even greater when the bonding area was the same. In the fracture test, the fracture would happen in the anchor since the structure size was small. When the structure was larger, the fracture happened in the cantilever beam, rather than the anchor. ? The Institution of Engineering and Technology 2014.; EI; 10; 660-663; 9
语种英语
DOI标识10.1049/mnl.2014.0251
内容类型其他
源URL[http://ir.pku.edu.cn/handle/20.500.11897/461496]  
专题信息科学技术学院
推荐引用方式
GB/T 7714
He, Jun,Huang, Xian,Zhang, Li,et al. Mechanical strength of anchor-microbeam combined structure fabricated by silicon-on-glass process. 2014-01-01.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace