Shock reliability of comb accelerometer
Jia Yubin ; Wang Shitao ; Huang Qinwen ; Hao Yilong
2013
关键词Accelerometer shock reliability stress strain beam
英文摘要Comb accelerometer structure includes mobile fingers connected with proof mass and fixed fingers linked with anchor. Under a huge shock, the reliability analysis of the accelerometer is reduced to the one of simple beam due to the stopper, i.e. shock response of double-clamped beam and single-clamped cantilever. From the quantitative analysis and numerical simulation in this paper, some useful conclusions are obtained: first damage or fracture for comb accelerometer is the finger beam rather than the bearing beam.; Automation & Control Systems; Computer Science, Interdisciplinary Applications; Engineering, Manufacturing; Engineering, Mechanical; EI; CPCI-S(ISTP); 0