The improvements at CSNS ion source | |
Chen, W.; Xue, K.; Lv, Y.; Cao, X.; Xiao, Y.; Huang, T.; Ouyang, H.; Chen WD(陈卫东); Liu, S.; Xue KJ(薛康佳) | |
刊名 | AIP CONFERENCE PROCEEDINGS |
2018 | |
卷号 | 2011页码:50022 |
ISSN号 | 0094-243X |
DOI | 10.1063/1.5053320 |
文献子类 | Proceedings Paper |
英文摘要 | The commissioning of CSNS front end has been finished. The 15 mA beam intensity is obtained at the end of RFQ. For CSNS ion source, it is a type of penning surface plasma ion source, similar to ISIS ion source. To improve the operation stability and reduce spark, sonic improvements have been made, including Penning field and extraction optics. The codes PBGUNS and CST are applied to simulate the beam extraction. With these simulation results, various extracted structures are modified, including the jaw gap of extractor and the gap of between plasma slit and extractor. The running results show the stability of ion source is improved further. |