Characterization of radiation damage caused by 23 MeV protons in Multi-Pixel Photon Counter (MPPC)
Lu, Xuefeng; Li, Zhengwei; Xu, Yupeng; Liu, Congzhan; Gu, Yudong; Xie, Fei; Li, Yanguo; Hu, Hongliang; Zhou, Xu; Li, Xufang
刊名NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
2016
卷号822页码:63-70
关键词SiPM MPPC Radiation damage Space application
ISSN号0168-9002
DOI10.1016/j.nima.2016.03.092
英文摘要A automatic gain control system (AGC) is designed to continuously monitor and automatically control the gain of the phoswich detectors onboard the Hard X-ray Modulation Telescope (HXMT). It consists of a Am-241 radioactive source and a photo-detector. The Am-241 radioactive source is tagged within a plastic scintillator (BC440M). The scintillating photons produced by the decayed alpha particles from the radioactive source is readout by the photo-detector. The Multi-Pixel Photon Counter (MPPC) produced by Hamamatsu is used as the photo-detector for AGC. To verify the feasibility of its application in space environment, four MPPCs (S10362-33-050C) were irradiated by a beam of 23 MeV protons. The integrated proton fluence that exposed to the four MPPC samples are 1.0 x 10(8) p cm(-2), 2.0 x 10(8) p cm(-2), 4.0 x 10(8) p cm(-2) and 1.0 x 10(10) p cm(-2) respectively. It is found that the increment leakage current of the MPPC samples caused by irradiation damage increase linearly with the integrated fluence. The pulse-height resolution of the MPPC has deteriorated hardly after irradiation. When irradiated up to 1.1 x 10(9) cm(-2) 1 MeV equivalent neutrons, the MPPC completely lost its photon-counting capability but could still work as a photo-detector for AGC. The MPPC fails as a photo-detector for the AGC when the irradiated 1 MeV neutron equivalent fluences is up to 2.7 x 10(10) cm(-2). (C) 2016 Elsevier B.V. All rights reserved.
WOS研究方向Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Nuclear ; Physics, Particles & Fields
语种英语
WOS记录号WOS:000374660900009
内容类型期刊论文
源URL[http://ir.ihep.ac.cn/handle/311005/282197]  
专题硬X射线调制望远镜卫星
推荐引用方式
GB/T 7714
Lu, Xuefeng,Li, Zhengwei,Xu, Yupeng,et al. Characterization of radiation damage caused by 23 MeV protons in Multi-Pixel Photon Counter (MPPC)[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2016,822:63-70.
APA Lu, Xuefeng.,Li, Zhengwei.,Xu, Yupeng.,Liu, Congzhan.,Gu, Yudong.,...&Zhao, Jianling.(2016).Characterization of radiation damage caused by 23 MeV protons in Multi-Pixel Photon Counter (MPPC).NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,822,63-70.
MLA Lu, Xuefeng,et al."Characterization of radiation damage caused by 23 MeV protons in Multi-Pixel Photon Counter (MPPC)".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 822(2016):63-70.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace