英文摘要Reversed phase liquid chromatography-tandem mass spectrometry (rplc-ms/ms) was utilized to investigate peptide profiling and bioactivities of antler aqueous extract (aae), digested antler aqueous extract (aed) and powder (pd). a total of 23, 417 and 389 peptides, as well as 15, 146 and 75 collagen peptides were identified from aae, aed and pd, respectively. angiotensin converting enzyme (ace) inhibitory activity, dipeptidyl peptidase iv (dpp-iv) inhibitory activity, prolyl endopeptidase (pep) inhibitory activity and antioxidant activity were used to evaluate the bioactivities of aae, aed and pd, and it was found that the sequence of their bioactivities was aae < aed < pd. all the results above proved that aed released more collagen peptides and pd possessed better biological activities. it suggests that the two edible ways of antler are complemented each other and have their own advantages.
WOS关键词VELVET ANTLER ; ANTIOXIDANT ACTIVITY ; PROLYL OLIGOPEPTIDASE ; INHIBITORY PEPTIDES ; PROTEOME ANALYSIS ; CERVUS-ELAPHUS ; IN-VITRO ; YOGURT ; POLYPEPTIDE ; EXTRACT
WOS研究方向Chemistry
WOS类目Chemistry, Analytical
语种英语
出版者ELSEVIER SCIENCE INC
WOS记录号WOS:000455897800011
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2372908
专题大连化学物理研究所
通讯作者Jin Yan
作者单位Chinese Acad Sci, Key Lab Separat Sci Analyt Chem, Dalian Inst Chem & Phys, Dalian 116023, Peoples R China
推荐引用方式
GB/T 7714
Yu Yang,Yan Jia-Ze,Jin Yan. Identification of peptide profiling of deer antler by reversed phase liquid chromatography-tandem mass spectrometry and bioactivities in simulated gastrointestinal digestion[J]. Chinese journal of analytical chemistry,2018,46(4):601-608.
APA Yu Yang,Yan Jia-Ze,&Jin Yan.(2018).Identification of peptide profiling of deer antler by reversed phase liquid chromatography-tandem mass spectrometry and bioactivities in simulated gastrointestinal digestion.Chinese journal of analytical chemistry,46(4),601-608.
MLA Yu Yang,et al."Identification of peptide profiling of deer antler by reversed phase liquid chromatography-tandem mass spectrometry and bioactivities in simulated gastrointestinal digestion".Chinese journal of analytical chemistry 46.4(2018):601-608.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace