Metabolic profiling of plasma by gas chromatography/time-of-flight mass spectrometry: method develop and validation
Li X(李响) ; Lu X(路鑫) ; Xu GW(许国旺)
2009-11-25
会议名称the 13th beijing conference and exhibition on instrumental analysis
会议日期2009-11-25
会议地点中国
页码466/2
通讯作者许国旺
中文摘要d59 metabolic profiling of plasma by gas chromatography/time-of-flight mass spectrometry: method develop and validation xiang li, xin lu, guowang xu national chromatographic r & a center, dalian institute of chemical physics, the chinese academy of sciences, dalian 116023, china metabonomics has been developed to investigate the metabolic changes coupled with pathophysiologic stimuli or genetic modification. gas chromatography/time-of-flight mass spectrometry (gc-tofms) has the advantages of high sensitivity, large linear range and fast acquisition rates, which are suitable for comprehensive, non-target analysis of biofluids in metabonomics. in our study, a metabolic profiling method of plasma is developed and validated with gc-tofms, indicating high sensitivity, good resolution and high throughput. 1 experimental three internal standards were added into plasma. methanol was added in, and then the mixture was centrifuged to discard protein. supernatant was lyophilized and derivatized by bis(trimethylsilyl)trifluoroacetamide (bstfa, pyridine was added as solvent). plasma samples were analyzed by a leco pegasus 4d gc×gc-tofms instrument (leco corporation, used in gc-tofms mode). a 30m×250 μm×0.25 μm db-5ms column was used in the agilent 6890n gc. helium was used as the carrier gas. mass spectra of m/z 33–600 were collected. 2 results sample preparation and chromatographic conditions were optimized based on the peak number, peak intensity and the resolution of both internal standards and plasma metabolites. an optimal result of separation and detection of the metabolites could be gained with the method above (figure 1). three internal standards were well distributed in the chromatogram. the metabolites could be separated with high resolution, including more than two hundred metabolites. to validate the method, limit of detection, recovery, linearity and precision were calculated according to the three internal standards. a good recovery (79.83±8.16%), precision (<5%) and linear range (r2>0.98) could be gained. these results indicated that a comprehensive and accurate metabolic profiling could be achieved by our method. this method could be further applied to wide fields of metabonomics researches as a standard operating procedure. figure 1. typical gc-tofms chromatogram of plasma. references 1. philippe a. guy, isabelle tavazzi, stephen j. bruce, ziad ramadan, sunil kochhar. j. chromatogr. b, 871: 253–260 (2008). 2. paul begley, sue francis-mcintyre, warwick b. dunn, david i. broadhurst, antony halsall, andy tseng, joshua knowles, husermet consortium, royston goodacre, douglas b. kell. anal. chem. 81: 7038–7046 (2009) 3. joachim kopka. j. biotechnol. 124: 312–322 (2006).
会议主办者中国分析测试协会
学科主题物理化学
语种中文
内容类型会议论文
源URL[http://159.226.238.44/handle/321008/113726]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
推荐引用方式
GB/T 7714
Li X,Lu X,Xu GW. Metabolic profiling of plasma by gas chromatography/time-of-flight mass spectrometry: method develop and validation[C]. 见:the 13th beijing conference and exhibition on instrumental analysis. 中国. 2009-11-25.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace