Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts | |
Ji, Dong-Jiang1,2; Qu, Gang-Rong1,3; Hu, Chun-Hong4; Liu, Bao-Dong5,6,7; Jian, Jian-Bo8; Guo, Xiao-Kun9 | |
刊名 | Chinese physics b
![]() |
2017-06-01 | |
卷号 | 26期号:6页码:8 |
关键词 | Sart Anisotropic tv In-line phase-contrast |
ISSN号 | 1674-1056 |
DOI | 10.1088/1674-1056/26/6/060701 |
通讯作者 | Qu, gang-rong(grqu@bjtu.edu.cn) |
英文摘要 | In-line phase-contrast computed tomography (il-pc-ct) imaging is a new physical and biochemical imaging method. il-pc-ct has advantages compared to absorption ct when imaging soft tissues. in practical applications, ring artifacts which will reduce the image quality are commonly encountered in il-pc-ct, and numerous correction methods exist to either pre-process the sinogram or post-process the reconstructed image. in this study, we develop an il-pc-ct reconstruction method based on anisotropic total variation (tv) minimization. using this method, the ring artifacts are corrected during the reconstruction process. this method is compared with two methods: a sinogram preprocessing correction technique based on wavelet-fft filter and a reconstruction method based on isotropic tv. the correction results show that the proposed method can reduce visible ring artifacts while preserving the liver section details for real liver section synchrotron data. |
WOS关键词 | IMAGE-RECONSTRUCTION ; REMOVAL ; CT ; MODEL |
WOS研究方向 | Physics |
WOS类目 | Physics, Multidisciplinary |
语种 | 英语 |
出版者 | IOP PUBLISHING LTD |
WOS记录号 | WOS:000403058100001 |
内容类型 | 期刊论文 |
URI标识 | http://www.corc.org.cn/handle/1471x/2177280 |
专题 | 高能物理研究所 |
通讯作者 | Qu, Gang-Rong |
作者单位 | 1.Beijing Jiaotong Univ, Sch Sci, Beijing 100044, Peoples R China 2.Tianjin Univ Technol & Educ, Sch Sci, Tianjin 300222, Peoples R China 3.Beijing Ctr Math & Informat Interdisciplinary Sci, Beijing 100048, Peoples R China 4.Tianjin Med Univ, Coll Biomed Engn, Tianjin 300070, Peoples R China 5.Chinese Acad Sci, Inst High Energy Phys, Div Nucl Technol & Applicat, Beijing 100049, Peoples R China 6.Beijing Engn Res Ctr Radiog Tech & Equipment, Beijing 100049, Peoples R China 7.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 8.Tianjin Med Univ, Radiat Oncol Dept, Gen Hosp, Tianjin 300052, Peoples R China 9.Tianjin Med Univ, Hosp 2, Tianjin 300070, Peoples R China |
推荐引用方式 GB/T 7714 | Ji, Dong-Jiang,Qu, Gang-Rong,Hu, Chun-Hong,et al. Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts[J]. Chinese physics b,2017,26(6):8. |
APA | Ji, Dong-Jiang,Qu, Gang-Rong,Hu, Chun-Hong,Liu, Bao-Dong,Jian, Jian-Bo,&Guo, Xiao-Kun.(2017).Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts.Chinese physics b,26(6),8. |
MLA | Ji, Dong-Jiang,et al."Anisotropic total variation minimization approach in in-line phase-contrast tomography and its application to correction of ring artifacts".Chinese physics b 26.6(2017):8. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论