CORC  > 高能物理研究所
Application of direct demodulation technique in analysis of ground verification test of x-ray spectrometer for chang'e mission
Zhang Jia-yu; Wang Huan-yu; Zhang Cheng-mo; Liang Xiao-hua; Yang Jia-wei; Wang Jin-zhou; Cao Xue-lei; Gao Min; Cui Xing-zhu; Peng Wen-xi
刊名Spectroscopy and spectral analysis
2008-10-01
卷号28期号:10页码:2450-2454
关键词X-ray spectrometer Verification test Quantitative analysis
ISSN号1000-0593
DOI10.3964/j.issn.1000-0593(2008)10-2450-05
通讯作者Zhang jia-yu(zhangjiayu@mail.ihep.ac.cn)
英文摘要An x-ray fluorescence imaging spectrometer based on silicon pin photodiodes was designed and constructed for the chang'e mission,. the first lunar spacecraft, and will be in operation at a 200 km circular lunar orbit with one year lifetime. the x-ray fluorescence spectrometer consists of two silicon pin photodiodes modules, each holds two low energy detector units to analyze the distribution of useful elements and to estimate the abundance on the moon, which is one of the objectives of the x-ray fluorescence spectrometer experiment. the low energy detector unit is 25 mm(2), 500 mu m thick, with the energy band of 1-10 kev, and energy resolution of: similar to 5% at s. 9 kev. the ground verification tests of the x-ray spectrometer for chang'e mission were introduced in the present paper. taking the energy response matrix of the spectrometer as the foundation and using the direct demodulation technique and fundamental parameter method, the authors performed some quantitative and qualitative analysis of these scientific data which came from the ground verification tests, especially for mg, al and si elements.
WOS研究方向Spectroscopy
WOS类目Spectroscopy
语种英语
出版者BEIJING UNIV PRESS
WOS记录号WOS:000260697000055
内容类型期刊论文
URI标识http://www.corc.org.cn/handle/1471x/2175879
专题高能物理研究所
通讯作者Zhang Jia-yu
作者单位Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophys, Beijing 100049, Peoples R China
推荐引用方式
GB/T 7714
Zhang Jia-yu,Wang Huan-yu,Zhang Cheng-mo,et al. Application of direct demodulation technique in analysis of ground verification test of x-ray spectrometer for chang'e mission[J]. Spectroscopy and spectral analysis,2008,28(10):2450-2454.
APA Zhang Jia-yu.,Wang Huan-yu.,Zhang Cheng-mo.,Liang Xiao-hua.,Yang Jia-wei.,...&Peng Wen-xi.(2008).Application of direct demodulation technique in analysis of ground verification test of x-ray spectrometer for chang'e mission.Spectroscopy and spectral analysis,28(10),2450-2454.
MLA Zhang Jia-yu,et al."Application of direct demodulation technique in analysis of ground verification test of x-ray spectrometer for chang'e mission".Spectroscopy and spectral analysis 28.10(2008):2450-2454.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace