Homogeneous time-resolved fluoroimmunoassay of bensulfuron-methyl by using terbium fluorescence energy transfer | |
Wang, GL; Yuan, JL; Matsumoto, K; Hu, ZD | |
刊名 | talanta |
2001-12-24 | |
卷号 | 55期号:6页码:1119-1125 |
关键词 | homogeneous immunoassay fluorescence energy transfer terbium bensulfuron-methyl |
英文摘要 | a sensitive homogenous time-resolved fluoroimmunoassay (tr-fia) method for bensulfuron-methyl (bsm) based on fluorescence resonance energy transfer (fret) from a tb3+ fluorescent chelate with n,n,n',n'-[2,6-bis(3'-aminomethyl-1'-pyrazoly)-4-phenylpyridine] tetrakis(acetic acid) (bpta-tb3+) to organic dye, cy3 or cy3.5 has been developed. new method combined the use of bpta-tb3+ labeled streptavidin, cy3 or cy3.5 labeled anti-bsm monoclonal antibody and biotinylated bsm-bsa conjugate (bsa is bovine serum albumin) for competitive-type immunoassay. after bpta-tb3+ labeled streptavidin was reacted with a competitive immune reaction solution containing biotinylated bsm-bsa, bsm sample and cy3 or cy3.5 labeled anti-bsm monoclonal antibody, the sensitized and long-lived emission of cy3 or cy3.5 derived from fret was measured, and thus the concentration of bsm in sample was calculated. the present method has the advantages of rapidity, simplicity and high sensitivity since the b/f (bound reagent/free reagent) separation steps and the solid-phase carrier are not necessary. the method gives the detection limit of 2.10 ng ml(-1). the coefficient variations of the method are less than 1.5% and the recoveries are in the range of 95-105% for bsm water sample measurement. (c) 2001 elsevier science b.v. all rights reserved. |
WOS标题词 | science & technology ; physical sciences |
类目[WOS] | chemistry, analytical |
研究领域[WOS] | chemistry |
关键词[WOS] | europium chelate ; immunoassays ; labels ; assays |
收录类别 | SCI |
原文出处 | true |
语种 | 英语 |
WOS记录号 | WOS:000173038600012 |
公开日期 | 2010-11-30 |
内容类型 | 期刊论文 |
源URL | [http://159.226.238.44/handle/321008/91799] |
专题 | 大连化学物理研究所_中国科学院大连化学物理研究所 |
作者单位 | 1.Chinese Acad Sci, Dalian Inst Chem Phys, Dept Analyt Chem, Dalian 116012, Peoples R China 2.Lanzhou Univ, Dept Chem, Lanzhou 730001, Peoples R China 3.Waseda Univ, Dept Chem, Shinjuku Ku, Tokyo 1698555, Japan |
推荐引用方式 GB/T 7714 | Wang, GL,Yuan, JL,Matsumoto, K,et al. Homogeneous time-resolved fluoroimmunoassay of bensulfuron-methyl by using terbium fluorescence energy transfer[J]. talanta,2001,55(6):1119-1125. |
APA | Wang, GL,Yuan, JL,Matsumoto, K,&Hu, ZD.(2001).Homogeneous time-resolved fluoroimmunoassay of bensulfuron-methyl by using terbium fluorescence energy transfer.talanta,55(6),1119-1125. |
MLA | Wang, GL,et al."Homogeneous time-resolved fluoroimmunoassay of bensulfuron-methyl by using terbium fluorescence energy transfer".talanta 55.6(2001):1119-1125. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论