Determination of boron concentration in uranium fuel samples by ICP-OES following a separation step by cation exchange resin
Luo, Y; Cong, HX; Cui, RR; Cao, CQ; Zhou, W; Zhao, ZQ
刊名NUCLEAR SCIENCE AND TECHNIQUES
2018
卷号29期号:3页码:-
关键词Plasma-mass Spectrometry Atomic-absorption-spectrometry Ion-exchange Emission-spectrometry Trace Amounts Water Mannitol Complex Acid Spectrophotometry
ISSN号1001-8042
DOI10.1007/s41365-018-0374-4
文献子类期刊论文
英文摘要The boron content of uranium fuel samples with boron concentrations in the range of 0.05-10 mu g/g was determined using inductively coupled plasma optical emission spectrometry (ICP-OES) after the uranium was separated by cation exchange. The samples were dissolved in 3 M HNO3 on a hot plate at 150 degrees C and evaporated to near dryness. The residues were redissolved in 0.2 M HNO3 and passed through a column loaded with Dowex 50WX8-400 resin. Uranium was adsorbed on the resin, while boron was easily eluted with 0.2 M HNO3. The boron content of the effluent was determined using ICP-OES. Several strategies were employed to improve the reliability of the experimentally determined boron content. The addition of mannitol and proper control of the evaporation process were shown to be effective in preventing boron loss during sample dissolution and evaporation. The memory effect was eliminated by flushing the system with 1.5% ammonia for 30 s between successive sample runs, and the matrix match method was used to eliminate the matrix effect arising from mannitol during the ICP-OES analysis. The accuracy of the results of the analysis was determined by addition recovery tests and by comparison with the results of three Chinese certified reference materials (GBW04242, GBW04243, and GBW04232). Using the method we developed, the limit of detection for boron was as low as 0.05 mu g/g in uranium fuel samples, and the relative standard deviations for 0.1-0.5 g uranium samples with 0.05-2 mu g/g of boron were within 9%.
语种英语
WOS记录号WOS:000428976900014
内容类型期刊论文
源URL[http://ir.sinap.ac.cn/handle/331007/28964]  
专题上海应用物理研究所_中科院上海应用物理研究所2011-2017年
作者单位1.Luo, Y
2.Cong, HX
3.Cui, RR
4.Cao, CQ
5.Zhou, W
6.Zhao, ZQ
推荐引用方式
GB/T 7714
Luo, Y,Cong, HX,Cui, RR,et al. Determination of boron concentration in uranium fuel samples by ICP-OES following a separation step by cation exchange resin[J]. NUCLEAR SCIENCE AND TECHNIQUES,2018,29(3):-.
APA Luo, Y,Cong, HX,Cui, RR,Cao, CQ,Zhou, W,&Zhao, ZQ.(2018).Determination of boron concentration in uranium fuel samples by ICP-OES following a separation step by cation exchange resin.NUCLEAR SCIENCE AND TECHNIQUES,29(3),-.
MLA Luo, Y,et al."Determination of boron concentration in uranium fuel samples by ICP-OES following a separation step by cation exchange resin".NUCLEAR SCIENCE AND TECHNIQUES 29.3(2018):-.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace