Global calibration of non-overlapping cameras: State of the art | |
Chen SL(陈松林); Chen YL(陈月玲); Fu SP(付生鹏); Zhao JB(赵吉宾); Hu MB(胡茂邦); Xia RB(夏仁波) | |
刊名 | Optik |
2018 | |
卷号 | 158页码:951-961 |
关键词 | Global calibration Multi-camera vision systems Non-overlapping FOV |
ISSN号 | 0030-4026 |
通讯作者 | Xia RB(夏仁波) |
产权排序 | 1 |
中文摘要 | Multi-camera vision systems (MVS) have a larger field of view than a single camera and are often applied to acquire geometric information of large-scale objects or scenes. Data integration from multiple cameras is a very important part for vision systems which is usually solved by using a global calibration method. After installing the MVS, in some cases, cameras do not have a common field of view (CFV) or only a narrow CFV. Accurate global calibration of cameras with non-overlapping field of view (FOV) is a very challenging task. A variety of global calibration of non-overlapping multi-camera methods (GCNM) have been proposed to estimate the relative positions and orientations of cameras based on different types of media or techniques such as large-range measuring devices, large-scale calibration targets, optical mirrors, motion model, laser projection, visual measuring instruments, etc. However, the GCNM is not yet a completely solved problem. Choosing which type of GCNM method to use is highly dependent on the specific vision system. Thus, in this paper, we present a comparative review of different GCNM methods and analyze accuracy, range, defects, and applications. Researchers and developers can take it as background information for their future works. |
WOS标题词 | Science & Technology ; Physical Sciences |
类目[WOS] | Optics |
研究领域[WOS] | Optics |
关键词[WOS] | EXTERNAL PARAMETER CALIBRATION ; STEREO VISION SENSOR ; MULTI-CAMERA ; EXTRINSIC CALIBRATION ; MEASUREMENT SYSTEM ; PLANAR MIRRORS ; LOCALIZATION ; VIEW ; POSE ; FOV |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000430761500118 |
内容类型 | 期刊论文 |
源URL | [http://ir.sia.cn/handle/173321/21487] |
专题 | 沈阳自动化研究所_装备制造技术研究室 |
作者单位 | 1.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, 114 Nanta Street, Shenyang 110016, China 2.University of Chinese Academy of Sciences, 19 A Yuquan Rd, Beijing 100049, China |
推荐引用方式 GB/T 7714 | Chen SL,Chen YL,Fu SP,et al. Global calibration of non-overlapping cameras: State of the art[J]. Optik,2018,158:951-961. |
APA | Chen SL,Chen YL,Fu SP,Zhao JB,Hu MB,&Xia RB.(2018).Global calibration of non-overlapping cameras: State of the art.Optik,158,951-961. |
MLA | Chen SL,et al."Global calibration of non-overlapping cameras: State of the art".Optik 158(2018):951-961. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论