M-kit: A cell migration assay based on microfluidic device and smartphone
Yang, Ke1,2; Wu, Jiandong2; Peretz-Soroka, Hagit2; Zhu, Ling1; Li, Zhigang1; Sang, Yaoshuo1; Hipolito, Jolly2; Zhang, Michael3; Santos, Susy4,5; Hillier, Craig3
刊名BIOSENSORS & BIOELECTRONICS
2018-01-15
卷号99期号:页码:259-267
关键词Microfluidic Device Smartphone Cell Functional Assay Cell Migration Chemotaxis
DOI10.1016/j.bios.2017.07.064
文献子类Article
英文摘要Mobile sensing based on the integration of microfluidic device and smartphone, so-called MS2 technology, has enabled many applications over recent years, and continues to stimulate growing interest in both research communities and industries. In particular, it has been envisioned that MS2 technology can be developed for various cell functional assays to enable basic research and clinical applications. Toward this direction, in this paper, we describe the development of a MS2-based cell functional assay for testing cell migration (the Midt). The system is constructed as an integrated test kit, which includes microfluidic chips, a smartphone-based imaging platform, the phone apps for image capturing and data analysis, and a set of reagent and accessories for performing the cell migration assay. We demonstrated that the Mkit can effectively measure purified neutrophil and cancer cell chemotaxis. Furthermore, neutrophil chemotaxis can be tested from a drop of whole blood using the Midt with red blood cell (RBC) lysis. The effects of chemoattractant dose and gradient profile on neutrophil chemotaxis were also tested using the Midt. In addition to research applications, we demonstrated the effective use of the Mkit for on-site test at the hospital and for testing clinical samples from chronic obstructive pulmonary disease patient. Thus, this developed Mkit provides an easy and integrated experimental platform for cell migration related research and potential medical diagnostic applications.
WOS关键词POINT-OF-CARE ; NEUTROPHIL CHEMOTAXIS ; BIOMEDICAL-RESEARCH ; MINI-MICROSCOPE ; MOBILE PHONE ; BLOOD ; PLATFORM ; SYSTEM ; INFLAMMATION ; TUMOR
WOS研究方向Biophysics ; Biotechnology & Applied Microbiology ; Chemistry ; Electrochemistry ; Science & Technology - Other Topics
语种英语
WOS记录号WOS:000413284200036
资助机构Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; University of Manitoba ; University of Manitoba ; University of Manitoba ; University of Manitoba ; Mitacs ; Mitacs ; Mitacs ; Mitacs ; NSERC ; NSERC ; NSERC ; NSERC ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Natural Sciences and Engineering Research Council of Canada (NSERC)(RGPIN-2014-04789) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; Canadian Institutes of Health Research (CIHR)(CPG-134755) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; CMC Microsystems(3699) ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; Winnipeg Rh Institute Foundation ; University of Manitoba ; University of Manitoba ; University of Manitoba ; University of Manitoba ; Mitacs ; Mitacs ; Mitacs ; Mitacs ; NSERC ; NSERC ; NSERC ; NSERC
内容类型期刊论文
源URL[http://ir.hfcas.ac.cn:8080/handle/334002/33829]  
专题合肥物质科学研究院_应用技术研究所
作者单位1.Chinese Acad Sci, Hefei Inst Phys Sci, Inst Appl Technol, Hefei, Anhui, Peoples R China
2.Univ Manitoba, Dept Phys & Astron, Winnipeg, MB, Canada
3.Seven Oaks Gen Hosp, Winnipeg, MB, Canada
4.Victoria Gen Hosp, Winnipeg, MB, Canada
5.River Hts Ft Garry Community Areas, Winnipeg, MB, Canada
6.Univ Manitoba, Dept Biosyst Engn, Winnipeg, MB, Canada
7.Univ Manitoba, Dept Immunol, Winnipeg, MB, Canada
8.Univ Manitoba, Dept Biol Sci, Winnipeg, MB, Canada
推荐引用方式
GB/T 7714
Yang, Ke,Wu, Jiandong,Peretz-Soroka, Hagit,et al. M-kit: A cell migration assay based on microfluidic device and smartphone[J]. BIOSENSORS & BIOELECTRONICS,2018,99(无):259-267.
APA Yang, Ke.,Wu, Jiandong.,Peretz-Soroka, Hagit.,Zhu, Ling.,Li, Zhigang.,...&Lin, Francis.(2018).M-kit: A cell migration assay based on microfluidic device and smartphone.BIOSENSORS & BIOELECTRONICS,99(无),259-267.
MLA Yang, Ke,et al."M-kit: A cell migration assay based on microfluidic device and smartphone".BIOSENSORS & BIOELECTRONICS 99.无(2018):259-267.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace