Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF
Wu Y(武毅); Yu XL(余西龙); Li F(李飞); Frédéric Grisch
刊名Measurement Science and Technology
2018-01
卷号29期号:1页码:015204
关键词OH* chemiluminescence OH-PLIF acetone-PLIF kerosene-PLIF laminar flame speed
ISSN号0957-0233
DOI10.1088/1361-6501/aa92d7
英文摘要

The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

分类号二类
URL标识查看原文
WOS关键词BURNING VELOCITY ; ELEVATED-TEMPERATURES ; MIXTURES ; COMBUSTION ; PRESSURE ; FLUORESCENCE ; HYDROCARBONS ; METHANE/AIR ; IGNITION ; DILUTION
WOS研究方向Engineering, Multidisciplinary ; Instruments & Instrumentation
语种英语
WOS记录号WOS:000417988300001
内容类型期刊论文
源URL[http://dspace.imech.ac.cn/handle/311007/72205]  
专题力学研究所_高温气体动力学国家重点实验室
推荐引用方式
GB/T 7714
Wu Y,Yu XL,Li F,et al. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF[J]. Measurement Science and Technology,2018,29(1):015204.
APA Wu Y,Yu XL,Li F,&Frédéric Grisch.(2018).Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF.Measurement Science and Technology,29(1),015204.
MLA Wu Y,et al."Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF".Measurement Science and Technology 29.1(2018):015204.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace