Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second
Hui, Jie; Cao, Yingchun; Zhang, Yi; Kole, Ayeeshik; Wang, Pu; Yu, Guangli; Eakins, Gregory; Sturek, Michael; Chen, Weibiao; Cheng, Ji-Xin
刊名Sci Rep
2017
卷号7
通讯作者jcheng@purdue.edu
英文摘要Intravascular photoacoustic-ultrasound (IVPA-US) imaging is an emerging hybrid modality for the detection of lipid-laden plaques, as it provides simultaneous morphological and lipid-specific chemical information of an artery wall. Real-time imaging and display at video-rate speed are critical for clinical utility of the IVPA-US imaging technology. Here, we demonstrate a portable IVPA-US system capable of imaging at up to 25 frames per second in real-time display mode. This unprecedented imaging speed was achieved by concurrent innovations in excitation laser source, rotary joint assembly, 1 mm IVPA-US catheter size, differentiated A-line strategy, and real-time image processing and display algorithms. Spatial resolution, chemical specificity, and capability for imaging highly dynamic objects were evaluated by phantoms to characterize system performance. An imaging speed of 16 frames per second was determined to be adequate to suppress motion artifacts from cardiac pulsation for in vivo applications. The translational capability of this system for the detection of lipid-laden plaques was validated by ex vivo imaging of an atherosclerotic human coronary artery at 16 frames per second, which showed strong correlation to gold-standard histopathology. Thus, this high-speed IVPA-US imaging system presents significant advances in the translational intravascular and other endoscopic applications.
收录类别SCI
资助信息AHA Postdoctoral Fellowship; IUPUI Graduate Student Imaging Research Fellowship; [R01HL125385]
WOS记录号WOS:000400491100018
内容类型期刊论文
源URL[http://ir.siom.ac.cn/handle/181231/28418]  
专题上海光学精密机械研究所_空间激光信息技术研究中心
作者单位中国科学院上海光学精密机械研究所
推荐引用方式
GB/T 7714
Hui, Jie,Cao, Yingchun,Zhang, Yi,et al. Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second[J]. Sci Rep,2017,7.
APA Hui, Jie.,Cao, Yingchun.,Zhang, Yi.,Kole, Ayeeshik.,Wang, Pu.,...&Cheng, Ji-Xin.(2017).Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second.Sci Rep,7.
MLA Hui, Jie,et al."Real-time intravascular photoacoustic-ultrasound imaging of lipid-laden plaque in human coronary artery at 16 frames per second".Sci Rep 7(2017).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace