CORC  > 中国农业科学院  > 农业环境与可持续发展研究所
Analysis of Electric-Energy Utilization Efficiency in a Plant Factory with Artificial Light for Lettuce Production
Tong, Y.1; Yang, Q.1; Shimamura, S.2
刊名INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013
2014
卷号1037页码:277-283
关键词energy saving heat pump vapor pressure deficit leaf area index lettuce
ISSN号0567-7572
通讯作者Tong, Y.
英文摘要Plant factories with artificial light (PFALs) are gradually accepted for plant production in Asian countries, such as Japan, China and Korea. It is essential to use artificial light for plant production in a PFAL with opaque materials for the walls. Heat pumps are often used to remove extra heat generated especially by lamps to maintain an optimum air temperature. The cost of electric-energy consumed by lamps and heat pumps in a PFAL is high and the commercial use of PFAL is therefore limited. The objectives of this study were to analyze possible solutions for improving the electric-energy utilization efficiencies (EUE) by investigating those of fluorescent lamps and heat pumps as affected by the air temperature, etc. A PFAL with a volume of 1,429 m(3) located in Chiba, Japan with lettuce plants was used in this study. The results show that the EUE of the lamps, defined as ratio of fresh weight of lettuce to photosynthetic active radiation emitted, ranged from 0.9 to 34.9 g mol(-1) and increased with plant growth. The system coefficient of performance (COP) for cooling of the heat pumps ranged from 3.5 to 6.6 when the indoor air temperature was kept at about 21 degrees C and outdoor air temperature ranged between -7.3 degrees C and 25.8 degrees C. The COP increased with increasing indoor-outdoor air temperature difference and decreasing vapor pressure deficit. Based on the above analysis, possible solutions for improving the EUE in a PFAL are given in this paper to reduce the electric-energy consumption and running costs of a PFAL.
学科主题Agronomy ; Horticulture
语种英语
出版者INT SOC HORTICULTURAL SCIENCE
WOS记录号WOS:000357373600032
内容类型期刊论文
源URL[http://111.203.20.206/handle/2HMLN22E/19822]  
专题农业环境与可持续发展研究所
作者单位1.Chinese Acad Agr Sci, Inst Environm & Sustainable Dev Agr, Key Lab Energy Conservat & Water Treatment Agr St, Minist Agr, Beijing 100081, Peoples R China
2.Mirai Corp Ltd, Matsudo, Chiba 2702218, Japan
推荐引用方式
GB/T 7714
Tong, Y.,Yang, Q.,Shimamura, S.. Analysis of Electric-Energy Utilization Efficiency in a Plant Factory with Artificial Light for Lettuce Production[J]. INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013,2014,1037:277-283.
APA Tong, Y.,Yang, Q.,&Shimamura, S..(2014).Analysis of Electric-Energy Utilization Efficiency in a Plant Factory with Artificial Light for Lettuce Production.INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013,1037,277-283.
MLA Tong, Y.,et al."Analysis of Electric-Energy Utilization Efficiency in a Plant Factory with Artificial Light for Lettuce Production".INTERNATIONAL SYMPOSIUM ON NEW TECHNOLOGIES FOR ENVIRONMENT CONTROL, ENERGY-SAVING AND CROP PRODUCTION IN GREENHOUSE AND PLANT FACTORY - GREENSYS 2013 1037(2014):277-283.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace