题名 | 电站锅炉四小管失效分析; Failure analysis of four tube in power station boiler |
作者 | 左仁红 |
答辩日期 | 2016-03-17 ; 2015-09-10 |
导师 | 王磊 |
关键词 | 电站锅炉 四小管 失效分析 Power station boiler Four tube Failure analysis |
英文摘要 | 火力发电厂是我国供电主体,约占总体发电量的70%。大型火电厂的安全事关电网的安全运行,而火电厂中的锅炉运行的可靠性是影响发电厂运行可靠性的首要因素,尤其是锅炉四小管的损坏泄漏对机组的安全运行影响最大,是火力发电厂的常见事故,一般占机组故障的60%-70%。锅炉经常由于四小管设计、制造、安装、运行、修理改造、管理等环节的问题以及长期在高温、高压、腐蚀、冲刷等恶劣条件下运行等原因而造成爆管并导致停炉。只有掌握四小管各种类型爆管的失效机理,才能有的放矢开展监督检验工作,寻找有效的管理和技术防治对策,提高机组运行的可靠性,保障电网的稳定经济运行。 为了有效开展四小管失效分析,本文对四小管各种类型爆管...; Thermal power plant is the main power supply of our country, accounting for 70% of the total power generation. The safety of large thermal power plant is related to the safe operation of power grid. The reliability of boiler operation in the coal-fired power plant is the primary factor that affect the reliability of power plant operation, especially boiler four tubular damage and leakage iMPacting...; 学位:工程硕士; 院系专业:物理与机电工程学院_工程硕士(机械工程); 学号:X2010182020 |
语种 | zh_CN |
出处 | http://210.34.4.13:8080/lunwen/detail.asp?serial=52876 |
内容类型 | 学位论文 |
源URL | [http://dspace.xmu.edu.cn/handle/2288/134200] |
专题 | 物理技术-学位论文 |
推荐引用方式 GB/T 7714 | 左仁红. 电站锅炉四小管失效分析, Failure analysis of four tube in power station boiler[D]. 2016, 2015. |