CORC  > 厦门大学  > 医学院-已发表论文
A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture
Liang, Bowei ; Ding, Zhenqi ; Shen, Junguo ; Zhai, Wenliang ; Kang, Liangqi ; Zhou, Liang ; Sha, Mo ; Liang, Dongzhu ; Ding ZQ(丁真奇) ; Zhai WL(翟文亮) ; Kang LQ(康两期) ; Sha M(沙漠)
刊名http://dx.doi.org/10.1007/s00264-012-1529-2
2012-08
关键词INVASIVE STABILIZATION SYSTEM RETROGRADE INTRAMEDULLARY NAIL ANGLED BLADE PLATE FEMUR FRACTURES INTERNAL-FIXATION FLEXIBLE FIXATION LOCKING PLATES SCREWS
英文摘要[09z020]; An anatomical supra-condylar plate is designed and analysed by biomechanical testing. The biomechanical properties of the supra-condylar and condylar plate were compared in six matched pairs of cadaveric femurs. A transverse osteotomy gap was created to simulate an OTA/AO type A3 supracondylar fracture. The left and right specimens were fitted with supra-condylar and condylar plate, respectively. Nondestructive axial compression, three-point bending and torsion tests were performed, and the peak load of the bone-implant construction was measured. The fracture site suitable for supra-condylar plate application and its correlation with femoral length were calculated. The gender influence on it was also discussed. The difference of stiffness between the supra-condylar and condyle groups were not significant (P > 0.05) at 363.4 and 362.5 N/mm for compression, 229.5 and 237.6 N/mm in the sagittal plane and 195.5 and 188.4 N/mm in the coronal plane for three-point bending, and 7.5 and 7.9 Nm/deg for axial torsion, respectively. The peak load was 4438 +/- 136.15 N and 5215 +/- 174.33 N, respectively, for the two groups. The average extent of the fracture site suitable for the application of the supra-condylar plate was 70.86 +/- 4.61 mm. The femoral length and gender showed no influence on it. Despite the limited bone contact area provided by the supra-condylar plate, its construct stiffness is comparable to the condylar plate. The supra-condylar plate can be used to treat carefully-selected extra-articular supracondylar fractures.
语种英语
出版者INT ORTHOP
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/93334]  
专题医学院-已发表论文
推荐引用方式
GB/T 7714
Liang, Bowei,Ding, Zhenqi,Shen, Junguo,et al. A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture[J]. http://dx.doi.org/10.1007/s00264-012-1529-2,2012.
APA Liang, Bowei.,Ding, Zhenqi.,Shen, Junguo.,Zhai, Wenliang.,Kang, Liangqi.,...&沙漠.(2012).A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture.http://dx.doi.org/10.1007/s00264-012-1529-2.
MLA Liang, Bowei,et al."A distal femoral supra-condylar plate: biomechanical comparison with condylar plate and first clinical application for treatment of supracondylar fracture".http://dx.doi.org/10.1007/s00264-012-1529-2 (2012).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace