CORC  > 厦门大学  > 生命科学-已发表论文
Sensing HIV related protein using epitope imprinted hydrophilic polymer coated quartz crystal microbalance
Lu, Chun-Hua ; Zhang, Yan ; Tang, Shui-Fen ; Fang, Zhi-Bin ; Yang, Huang-Hao ; Chen, Xi ; Chen, Guo-Nan ; Lu CH(鲁春华)
刊名http://dx.doi.org/10.1016/j.bios.2011.11.008
2012-01-15
关键词SILICA NANOPARTICLES AU NANOPARTICLES COILED-COIL TYPE-1 GP41 RECOGNITION SURFACE ANTIBODY PEPTIDE MECHANISM MEMBRANES
英文摘要National Basic Research Program of China [2010CB732403]; National Natural Science Foundation of China [20975023]; program for new century excellent talents in university of China [09-0014]; National Science Foundation of Fujian Province [2010J06003]; We have developed a biomimetic sensor for the detection of human immunodeficiency virus type 1 (HIV-1) related protein (glycoprotein 41, gp41) based on epitope imprinting technique. gp41 is the transmembrane protein of HIV-1 and plays an important role in membrane fusion between viruses and infected cells. It is an important index for determining the extent of HIV-1 disease progression and the efficacy of therapeutic intervention. In this work, dopamine was used as the functional monomer and polymerized on the surface of quartz crystal microbalance (QCM) chip in the presence of template, a synthetic peptide with 35 amino acid residues, analogous to residues 579-613 of the gp41. This process resulted in grafting a hydrophilic molecularly imprinted polymer (MIP) film on the QCM chip. QCM measurement showed that the resulting MIP film not only had a great affinity towards the template peptide, but also could bind the corresponding gp41 protein specifically. The dissociation constant (K-d) of MIP for the template peptide was calculated to be 3.17 nM through Scatchard analysis, which was similar to those of monoclonal antibodies. Direct detection of the gp41 was achieved quantitatively using the resulting MIP-based biomimetic sensor. The detection limit of gp41 was 2 ng/mL, which was comparable to the reported ELISA method. In addition, the practical analytical performance of the sensor was examined by evaluating the detection of gp41 in human urine samples with satisfactory results. (C) 2011 Elsevier B.V. All rights reserved.
语种英语
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/65932]  
专题生命科学-已发表论文
推荐引用方式
GB/T 7714
Lu, Chun-Hua,Zhang, Yan,Tang, Shui-Fen,et al. Sensing HIV related protein using epitope imprinted hydrophilic polymer coated quartz crystal microbalance[J]. http://dx.doi.org/10.1016/j.bios.2011.11.008,2012.
APA Lu, Chun-Hua.,Zhang, Yan.,Tang, Shui-Fen.,Fang, Zhi-Bin.,Yang, Huang-Hao.,...&鲁春华.(2012).Sensing HIV related protein using epitope imprinted hydrophilic polymer coated quartz crystal microbalance.http://dx.doi.org/10.1016/j.bios.2011.11.008.
MLA Lu, Chun-Hua,et al."Sensing HIV related protein using epitope imprinted hydrophilic polymer coated quartz crystal microbalance".http://dx.doi.org/10.1016/j.bios.2011.11.008 (2012).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace